ManualsBrandsFriedrich ManualsAir Conditioners14,500 BTU Smart Packaged Terminal Air Conditioner with FriedrichLink Energy Management Thermostats, Heat Pump, Antimicrobial Air Filters, Electronic Defrost Control, Tangential Blower Wheel, Room Freeze Protection, Fresh Air Damper, Slinger Ring Technolo
4
General Specications
Installation Checklist
q Inspect all components and accessories for damage before and after
installation.
q Remove the cardboard wall sleeve support and grill weatherboard.
q Check for proper wall sleeve installation in accordance with the wall
sleeve installation instructions.
q Check for a subbase kit or other means of structural support which
is required for ALL installations projecting more than 8" into room.
q Install the recommended Condensate Drain Kits for complete
condensate removal.
q Ensure that the chassis is installed in a 16" high x 42” wide wall sleeve
that is no deeper than 13 ¾". A bafe kit is required if the sleeve
exceeds that depth.
q Ensure that chassis and chassis front cover are installed and secured
properly.
q Ensure that drapes, bed, bedspread, furniture, etc. DO NOT block
either return or discharge air grilles.
q Inspect the condenser air inlet and outlet for any obstructions
(shrubbery, etc.)
q Ensure that 'reset' button is pressed on LCD device (only on cord
connected models).
MODEL NUMBER
07 =7,000 Btuh
09 =9,000 Btuh
Nominal Capacity
12 =12,000Btuh
15 =15,000Btuh
Series
PD =Friedrich DigitalPTAC
System
E=Coolingwithorwithout electric heat
H= Heat Pump with AuxiliaryHeat
Voltage
K=230/208V - 1Ph. - 60 Hz.
R=265V - 1Ph. - 60 Hz.
NominalHeaterSize (230Vor265V)
2 = 2.5 KW 3 = 3.5 KW 5 = 5.0 KW*
* 5.0 kw only available on 9,000 12,000 and 15,000 BTU models
Chassis
S= Standard
Design Series
EngineeringDigit
PD
Note: All PTAC models with a C design series or
later come standard with Diamonblue seacost
protection and digital controls.
X = Accessory
E