ManualsBrandsFriedrich ManualsAir ConditionersHazardguard Series Window or Wall Air Conditioner with 23500 Cooling BTU, 385 CFM, 230 Volts, 9.7 EER Corrosion Protection, Hermetically Sealed Compressor, Diamonblue Advanced Corrosion Protection, Corrosion Resistance, UL Listed, Durability & Reliability
Table Of Contents
15
D E T A IL 16 - B
D E T A IL 1 6 - A
A
B
TOP ANGLE (ITEM #5)
CABNET
SILL PLATE TAB
SIDE ANGLE (ITEM #6)
2 REQUIRED
8-A X 3/8" LONG SCREW
(ITEM #7) 2 REQUIRED
TAB
TAB
LOOP
Shell (Cabinet) Preparation for Installation
STEP 1 Remove still plate and bend the taps up and reinstall 4” back from original shipping position. Move shell guides 4” forward (to
the forward-most hole in the shell rail). See (DETAIL 16-A).
STEP 2 Take the side angles (item #6) and engage its loops in the tabs (both sides) of the sill plate. (DETAIL 16-A).
STEP 3 Take the top Flange (item #5) and engage its tabs in the top loops of the side anges (DETAIL 16-B).
STEP 4 Install two (2) screws (Item #7) to secure the top angle tabs and the side angle in the side of the cabinet (Detail 16-B).
Figure 16