Model P09B P12B PH14B
PERFORMANCE
Cooling Capacity Btu 9300 11600 13500
Heating Capacity Btu 10700
Energy Efciency Rating EER 9.4 8.8 9.5
Coefcient of Performance COP 2.8
Air Movement CFM 212 235 250
Moisture Removal Pts/hr. 5.0 6.0 6.0
SPECIFICATIONS
Refrigerant Type R-410A
Power Supply Volts 115
Rated Current
Cooling Amps 10.8 11.5 10.8
Heating Amps 10.8
Watts 989 1318 1421/1120
Dimensions (Inches) W x H x D 19 1/2 x 33 1/2 x 15 1/2
Weight (Net/Shipping) Lbs. 71/89 72/90 78/95
Carton Dimensions (Inches) W x H x D 20 7/8 x 43 1/8 x 16 3/4
Model
Circuit Rating
Breaker or T-D
Fuse
Plug
Face
(NEMA#)
Wall Outlet
Appearance
Power
cord
length
P09B,
P12B,
PH14B
125V - 15A 5 - 15P 6 ft.
Features/Installation/Specifications
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
LISTED
PORTABLE AIR CONDITIONERS
183H
Installation Kit
INSTALLATION KIT- Dual intake and exhaust
hoses. Flexible, heavy duty intake/exhaust
hoses extend from 24” to 60. The hoses can
be vented through a window or through a wall
opening to the outside.
WINDOW SLIDER KIT (Included)
Fits HORIZONTAL or VERTICAL WINDOWS
WINDOW OPENING:
Minimum: 26"*
Maximum: 46"
* Window slider kit can be trimmed to t a smaller
opening.
NOTE: Air conditioners will provide cooling at outdoor temperatures down to 41� F and
heat pumps will provide heating at outdoor temperatures down to 14� F with single hose installation.
Ideal Applications
• Supplemental or emergency
cooling or heating anywhere
• Temporary cooling in computer rooms
• Guard buildings
• Construction trailers/RVs
• Workshops and garages
• Home ofces
• Dorm rooms
• Bedrooms, attics and basements
• Sunrooms/enclosed patios
Installation Features
• Plugs into standard 115 volt outlet
• Easy-roll casters for portability
• All installation accessories included
• Window kit ts both vertical and horizontal
standard and some casement slider windows
• 6 ft. long power cord
LISTED
PORTABLE AIR CONDITIONERS
183H
Extreme A/C for Hazardous Conditions
Hazardgard
®
is specically designed to cool living quarters, storage areas and
other enclosures situated in hazardous locations, where specic volatile ammable
liquids or gases are handled or used within enclosed containers or systems.
Hazardgard meets T4 temperature classication which means unit surface tem-
peratures will not rise above 135° C/275° F. (note: 50/60Hz model listed as T4A
for surface temperatures to 120° C/248° F). Operates at low ambient conditions
without freezing at outdoor ambient temperatures as low as 7° C/45° F. Tolerates
higher outdoor temperatures up to 55° C /130° F.
Equipment is certified in accordance with ISA 12.12.01 and NFPA 70
(National Electric Code)
ARTICLE 501 ARTICLE 505
Class I, Div. 2, Group A and Group B Class I, Zone 2, Group IIC
Class I, Div. 2, Group B Class I, Zone 2, Group IIB
plus hydrogen, or “+H2”
Class I, Div. 2, Group C Class I, Zone 2, Group IIB
Class I, Div. 2, Group D Class I, Zone 2, Group IIA
Equipment is certified in accordance with ANSI/UL 484 and SASO 2681
UL LISTED FOR CLASS 1, DIVISION 2,
GROUPS A, B, C AND D HAZARDOUS LOCATIONS.
Hazardous Location Room Air Conditioners
Hazardgard
®
60 Hertz models
North America
14000 to 24000 Btu
Up to 9.7 EER
50 Hertz models
International
19100 to 19500 Btu
Up to 9.0 EER
50-60 Hertz model
International-North America
50 Hertz 60 Hertz
21000/20500 Btu 24000/23700
8.1/8.5 EER 8.8/8.5 EER
28