Brochure
Model P09B P12B PH14B
PERFORMANCE
Cooling Capacity Btu 9300 11600 13500
Heating Capacity Btu — — 10700
Energy Efciency Rating EER 9.4 8.8 9.5
Coefcient of Performance COP — — 2.8
Air Movement CFM 212 235 250
Moisture Removal Pts/hr. 5.0 6.0 6.0
SPECIFICATIONS
Refrigerant Type R-410A
Power Supply Volts 115
Rated Current
Cooling Amps 10.8 11.5 10.8
Heating Amps — — 10.8
Watts 989 1318 1421/1120
Dimensions (Inches) W x H x D 19 1/2 x 33 1/2 x 15 1/2
Weight (Net/Shipping) Lbs. 71/89 72/90 78/95
Carton Dimensions (Inches) W x H x D 20 7/8 x 43 1/8 x 16 3/4
Model
Circuit Rating
Breaker or T-D
Fuse
Plug
Face
(NEMA#)
Wall Outlet
Appearance
Power
cord
length
P09B,
P12B,
PH14B
125V - 15A 5 - 15P 6 ft.
Features/Installation/Specifications
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
LISTED
PORTABLE AIR CONDITIONERS
183H
Installation Kit
INSTALLATION KIT- Dual intake and exhaust
hoses. Flexible, heavy duty intake/exhaust
hoses extend from 24” to 60”. The hoses can
be vented through a window or through a wall
opening to the outside.
WINDOW SLIDER KIT (Included)
Fits HORIZONTAL or VERTICAL WINDOWS
WINDOW OPENING:
Minimum: 26"*
Maximum: 46"
* Window slider kit can be trimmed to t a smaller
opening.
NOTE: Air conditioners will provide cooling at outdoor temperatures down to 41� F and
heat pumps will provide heating at outdoor temperatures down to 14� F with single hose installation.
Ideal Applications
• Supplemental or emergency
cooling or heating anywhere
• Temporary cooling in computer rooms
• Guard buildings
• Construction trailers/RVs
• Workshops and garages
• Home ofces
• Dorm rooms
• Bedrooms, attics and basements
• Sunrooms/enclosed patios
Installation Features
• Plugs into standard 115 volt outlet
• Easy-roll casters for portability
• All installation accessories included
• Window kit ts both vertical and horizontal
standard and some casement slider windows
• 6 ft. long power cord
LISTED
PORTABLE AIR CONDITIONERS
183H
Extreme A/C for Hazardous Conditions
Hazardgard
®
is specically designed to cool living quarters, storage areas and
other enclosures situated in hazardous locations, where specic volatile ammable
liquids or gases are handled or used within enclosed containers or systems.
Hazardgard meets T4 temperature classication which means unit surface tem-
peratures will not rise above 135° C/275° F. (note: 50/60Hz model listed as T4A
for surface temperatures to 120° C/248° F). Operates at low ambient conditions
without freezing at outdoor ambient temperatures as low as 7° C/45° F. Tolerates
higher outdoor temperatures up to 55° C /130° F.
Equipment is certified in accordance with ISA 12.12.01 and NFPA 70
(National Electric Code)
ARTICLE 501 ARTICLE 505
Class I, Div. 2, Group A and Group B Class I, Zone 2, Group IIC
Class I, Div. 2, Group B Class I, Zone 2, Group IIB
plus hydrogen, or “+H2”
Class I, Div. 2, Group C Class I, Zone 2, Group IIB
Class I, Div. 2, Group D Class I, Zone 2, Group IIA
Equipment is certified in accordance with ANSI/UL 484 and SASO 2681
UL LISTED FOR CLASS 1, DIVISION 2,
GROUPS A, B, C AND D HAZARDOUS LOCATIONS.
Hazardous Location Room Air Conditioners
Hazardgard
®
60 Hertz models
North America
14000 to 24000 Btu
Up to 9.7 EER
50 Hertz models
International
19100 to 19500 Btu
Up to 9.0 EER
50-60 Hertz model
International-North America
50 Hertz 60 Hertz
21000/20500 Btu 24000/23700
8.1/8.5 EER 8.8/8.5 EER
28