Step 6: Adjust the Divider
NOTE Let the caulk cure completely before installing
the chassis. This completes the plenum installation.
Adjustment
Loosen the two screws located on the top side of the divider.
Slide the top part of the divider toward the outside until the
sealing strip makes contact with the outdoor louver. Tighten
the divider screws to complete the adjustment.
Condensate Disposal Preparation
for VHA09 and VHA12 Models
IMPORTANT This step must be performed to ensure that the
chassis installs and seals properly in the wall plenum.
If provisions for condensate disposal are made prior to chassis
installation and the drain is to be located beneath the platform
for the unit, use the accompanying drawing as a guide for cut-
out locations. Only one drain per unit is required.