Service and Parts Manual (2016, 2017, 2018, 2014, 2015, 2013, 2012)

Table Of Contents
87 PB
AVAILABLE ACCESSORIES
Thermostat - Rt6
Specifications
Electrical rating:
for 5 seconds)
Backlight Operation: 10 seconds
Terminations: R, C, GL, GH, O/B, Y, W
24 VAC (18-30 VAC)
1 amp maximum per terminal
3 amp maximum total load
Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
System configurations: 2-stage heat, 1-stage cool, heat pump, electric
Timing: Anti-short cycle: 4 minutes (bypass anti-short cycle delay by returning to OFF mode
Package Contents/Tools Required
Important Safety Information
or removing thermostat.
WARNING!
:
Always turn o power at the main power supply before installing, cleaning,
Package includes: RT6 thermostat on base, thermostat cover, wiring labels, screws and wall
anchors, Installation, Operation and Application Guide
Tools required for installation: Drill with 3/16” bit, hammer, screwdriver
To Remove Existing Thermostat
ELECTRICAL SHOCK HAZARD
– Turn o power at the main service panel by removing
the fuse or switching the appropriate circuit breaker to the OFF position before
removing the existing thermostat.
This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
All wiring must conform to local and national electrical and building codes
Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage
your A/C system and cause personal injuries
Use this thermostat only as described in this manual
1. Turn o power to the heating and cooling system by removing the fuse or switching the appropriate
circuit breaker o.
2. Remove cover of old thermostat. This should expose the wires.
3. Label the existing wires with the enclosed wire labels before removing wires.
4. After labeling wires, remove wires from wire terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to install this thermostat.