Terminal Designator Descriptions
R 24 VAC hot
C 24 VAC common
O/B Configurable
O – Cool active reversing valve
B – Heat active reversing valve
RT6P Output Chart
Y 1st stage cool, 1st stage heat for heat pumps
W 1st stage heat for non-heat pump systems, auxiliary heat for HP systems
GL Low fan
GH High fan
OFF
Configuration Mode
Press the up or down button to change settings within each screen.
Press the button to advance to the next screen.
To exit configuration mode, press the CONFIG switch for 1 second.
Pressing the
left
button will return you to the previous screen.
Down
button
Up
button
Left
button
Right
button
The configuration mode is used to set the RT6P to match your heating/cooling system. The RT6P
functions with heat pump, air conditioning, or electric heat systems.
Note:
Thermostat comes configured for 1-stage heat / 1-stage cooling for use with all heat/cool and
single-stage heat pump models. For Friedrich PTHP models follow the instructions below to
configure the thermostat for two-stage heat pump operation using the ‘O’ terminal.
To configure the RT6P , perform the following steps:
CONFIG
Wiring Diagrams
Heat/Cool Systems
1. Verify the RT6P is in the OFF mode.
Press the SYS (left) button until o mode displays.
2. Remove the cover of the thermostat by gently pulling near one of the
corners at the top of the thermostat.
3. Press the CONFIG button for 1 second while the RT6P is in OFF mode.
Heat pump with electric backup
Configuration 1
ST
Cool 1
ST
Heat 2
ND
Heat
ELC Y, G W, G, B N/A
HP ‘O’ config Y, G, O Y, G Y, W, G
HP ‘B’ config Y, G Y, G, B Y, G, B, W
The RT6P thermostat is configurable for dierent systems. The configuration directly aects the outputs.
Use the output chart to correctly configure and wire the thermostat to your system.