Accessory VPDP2 Manual (2020)

STEP 1: CUT OPENING IN GASKET
Remove an 8 1/8" portion of the weather seal gasket from the bottom right surface of the plenum.
To remove: Cut the gasket in the lower right corner of the plenum. Then make a second cut 8 1/8" from the
right corner. The gasket should peel away from the plenum leaving a clean mounting surface (See detail A).
STEP 2: SEAL AND SET PAN
Prior to placing the drain pan into the opening run a 1/4" bead of sealant the entire width of the removed
gasket. The pan should be placed against the right edge of the plenum and the secondary overow lip
inserted into the plenum NO DEEPER THAN 1.5 INCHES to prevent water leaks (See Detail B).
A
DETAIL A
8.125
B
1.5”
B
Sealant
92015003_01
Installation Instructions
DRAIN PAN
For VHA18 and VHA24 units only.
Please read these instructions completely before attempting installation.
NOTE: This drain pan must be installed with all VHA18 and VHA24 units manufactured after September 2019
(model number ends with 'RTP').
Model VPDP2

Summary of content (4 pages)