Submittal Sheet

ChassisrequiresWSEsleeve(soldandshippedseparately)
SleeveDimensions
Friedrich
WSESleeve
Fedders
A Sleeve
Fedders
BSleeve
Height(inches) 163/4 163/4 163/4
Width(inches) 27 27 27
Depth(inches) 163/4 163/4 193/4
FITSEXISTINGFEDDERSSLEEVES.
Height W i d t h  Depth
Height
ofFront
Widthof
Front
Depth
with
Front
Minimum
ExtensionIntoRoom
withFront
Chassis 153/4" 261/2" 161/4" 171/4" 271/2" 231/4" 71/2"
CHASSISDIMENSIONS
Model
Height W i d t h  Depth
Depth
with
Front
Minimum
Extension
Outside
Thru-the-wall
FinishedHole
Height Width Max.Depth
WSESleeve 163/4" 27" 163/4" 241/4" 9/16" 171/4" 271/4" 155/16"
WSESLEEVEDIMENSIONS
Wallmaster
®
Thru-the-wall
Air Conditioners, Heat Pumps & Electric Heat models
Thru-the-wall_WallMaster_Submittal_2019
AG,Optional ArchitecturalGrille
Premiumbrushedaluminumgrille
WSEWALLSLEEVE
Standard Grille
Premium,stampedgalvanizedsteel
grillewithpowdercoatpaint.Ships
withsleeve.Galvanizedsteelinner
andouterweatherpanelsalsoship
withsleeve.
WallMaster
®
Optional Installation Accessories
DK/DrainKit
Installedatthebackoftheunitandallowsfor
attachmenttocondensatedisposalsystem,if
necessaryordesired.
IDK/InternalDrainKit
Newconstructionapplications
whereacondensatedrainsystem
hasbeenbuiltintothewallinterior.
BAK/BafeAdapterKit
Necessarywheninstalling
inasleevedeeperthan16
3/4"deep,suchasFedders
Bsleeve(193/4"deep).
IMPORTANT:
Operatingtheairconditioner
withincorrectreargrilleor
withoutBafeAdapterKit
(on193/4”deepsleeve)will
recirculatedischargeairand
causecompressoroverload
totrip.
Thiswillcausetheunit
toshutdowntemporarily
andmayleadtopremature
compressorfailure.
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers