Service and Parts Manual (2019, 2020, 2021, 2022)
122 PB
COMPONENTS TESTING
Check Fuse and Capacitor
Checking  continuity  of fuse  on  PCB  ASS’Y.
Remove  the PCB  ASS’Y  from the electrical  component  box.  Then pull out  the fuse
from the PCB ASS’Y (Fig.1)
Fuse
PCB Ass'Y
Fig.1
2) Check  for continuity  by a multimeter as shown in  Fig.2.
Fuse
Fig.2
.CAPACITOR
1) Remove  the  lead  wires  from  the  capacitor  terminals,  and  then  place  a probe  on
the capacitor  terminals as  shown  in Fig.3.
2) Observe  the  deflection  of  the  pointer,  setting  the  resistance  measuring  range  of
the multimeter  to the maximum  value.
3) The  capacitor  is “good” if the pointer bounces  to a great extent  and  then gradually
returns to its original position.
4) The  range  of deflection  and  deflection  time differ according  to the capacity  of the
capacitor.
Compressor motor 
capacitor
Fan motor
capacitor
Multimeter
Fig.3