OPERATION
Indoor Unit Control Mode
Main general technical parameters
  (1) Remote receiver distance: 8 m.
  (2) Remote receiver angle: Less than 80 degrees.
  (3) Temperature control accuracy: ±1℃.
  (4) Time error: Less than 1%.
Functions of the control function
  (1) Emergency switch 
  Pressing the emergency button can start or stop the unit, or the unit can start up according to the automatic mode of 
  operation. Press this button to turn ON the unit, the unit will run in auto mode, and press it again to turn the unit off. When 
  the unit is OFF, press and hold the emergency switch for 5 seconds, with 3 beeps, the indoor unit would turn to emergency 
  running. In such situation, the unit would be forced to turn to cooling operation with high speed, the flaps sweeping and the  
  unit’s operation is irrelevant with room temperature. 
  If a remote signal has been received during the emergency run, the machine will operate upon the command of such a 
  remote signal
  (2) Operator-machine communication.
  The air conditioner and remote controller is provided with a temperature sensor. The remote controller on the temperature 
  sensor detects the default settings of room temperature. If the indoor control unit has not received remote control signal 
  for a long time, it will automatically switch to the air conditioner body temperature sensor.
  (3) Timer function
 A. Timer on 
    When set to start in a time by the remote controller, the air conditioner starts in the timer on condition. When 
    the set time is up, the air conditioner will turn on and operates in the preset conditions after receiving a signal 
    from the remote controller. If the air conditioner has not received a signal from the remote controller when the 
    set time is up, it will automatically start and operate in the preset conditions.
 B. Timer off 
    When set to stop in a set time by the remote controller, the air conditioner will start in the timer off condition. 
    When the set time is up, the air conditioner will turn off after receiving a signal from the remote controller. If the
    air conditioner has not received a signal from the remote controller when the set time is up, it will turn off 
 automatically.
 C, Neither the turning on nor turning off operation will cancel the timer function.
  (4) Sleep
    A. In the heating, cooling or dehumidifying mode, press the “Sleep” button on the remote controller to start or
    cancel the sleep function in turn, and at the same time the sleep icon on the display screen will be on or off 
 accordingly.
    B. In the heating mode, the set temperature will decrease automatically after the sleep function is started.
    C. In the cooling mode, the set temperature will rise automatically after the sleep function is started.
    D. By default, the setting is to cancel the sleep function. Turning off the unit will also cancel the sleep function.
  (5) Highly efficient run function (only for some remote controller)
  In Cooling, Dehumidification, Fan mode, press the “HIGH POWER “ to enter the refrigeration mode, set the temperature 
  automatically adjusting to lowest temp; the Fan speed is powerful speed; frequency is high frequency operation. 
  In heating mode, press the “HIGH POWER” to enter the refrigeration mode, set the temperature automatically to adjust to 
  highest temp.; the Fan speed is powerful speed; frequency is high frequency operation. 
  Mute function (only for some remote controller) 
  In the indoor unit operation mode, you may turn on or turn off mute function with mute key. The air conditioner will run 
  with mute fan speed in mute mode.
  (6) Prevention cooling wind prevention mode 
  In the heating-run, to prevent the indoor fan from blowing cold air, the indoor fan will stop or run slowly until the coil is 
 warm. 
  (7) Blowing waste heating and waste cooling function
  In the heating mode,when the air conditioner is turned off, the indoor heat exchanger temperature is still higher, so the air 
  conditioner will to run the waste heat. 
  In the cooling and dehumidification mode, after the compressor stops, indoor unit will continue to set the speed of   
  operation for a period of time.
  (8) Dehumidifying method:
  If remote control setting is in dehumidifying mode, indoor unit is forced to run at low speed (high power key or a strong 
  bond also maintains a low wind speed), and the outdoor unit runs according to the refrigeration mode operation.