OPERATION
Control Logic Description
DC-Inverter outdoor unit :
Outdoor fan running rules:
Once the outdoor fan start up, it will follow the below rules:
Single outdoor fan: First, it will run in an invariable speed f or a short time; Then it will regulate
the speed by the indoor-coil temperature.
Double outdoor fan: If it has two outdoor fans, the upper fan regulates the speed by the rules,
and the downer fan speed lower than the upper fan speed for 30 r pm~60rpm.
Ts-T1 
0 
2
4 
Low 
Medium 
High 
Heating  Mode  
Indoor fan running rules: 
The  auto fan:  
T1 is indoor  room temperature.  Ts is setting temperature. 
The indoor unit fan will not run until the indoor unit heat heat exchanger reches a high enough temperature.
This is because the cold air prevention system is operating. After several minutes, the speed can be 
selected to high, medium, low, or auto.