Service and Parts Manual (2019, 2020, 2021, 2022)
81 PB
INSTALLATION
Checklist
Check Unit following Installation
No. Items to be checked Possible malfunction
1
Has the unit been 
installed firmly?
2
The unit may drop, shake or 
emit noise.
Have you done the 
refrigerant leakage test?
3
It may cause insufficient cooling 
(heating) capacity.
Is heat insulation of 
pipeline sufficient?
4
It may cause condensation and 
water dripping.
Is water drained well?
5
It may cause condensation and 
water dripping.
6
It may cause malfunction or 
damage the parts.
Is the voltage of power 
supply according to the 
voltage marked on the 
nameplate?
7
Is electric wiring and 
pipeline installed 
correctly?
It may cause malfunction or 
damage the parts.
It may cause electric leakage.
Is the unit grounded 
securely?
8
Does the power cord 
follow the specification?
9
It may cause malfunction or 
damage the parts.
Is there any obstruction 
in air inlet and air outlet?
10
It may cause insufficient cooling 
(heating).
11
It may cause malfunction or 
damaging the parts.
The dust and 
sundries caused 
during installation are 
removed?
The gas valve and liquid 
valve of connection pipe 
are open completely?
It may cause insufficient cooling 
(heating) capacity.