Service and Parts Manual (2019, 2020, 2021, 2022)
89 PB
R-410A SEALED SYSTEM REPAIR
Replace 36k Outdoor unit Compressor and Motor
Step  
disconnected and verified as voltage free.  
Important: Before disassembly and assembly, make sure that the power to the system has been 
Illustration  Handling Instruction  
casing
1. Remove external
2. Remove motor
1. Remove the top cover, 
handle and valve cover;
2. Remove the outer case
and right side plate.
3. Remove compressor
1. Remove the blade nut and
then remove the blade;
2. Remove the motor from
motor supporter
4. Assemble unit
Assemble the unit in the 
reverse  order of 
disassembly.  
1. Reclaim the ref rigerant
From the entire system.
2. Unsolder  the 4-way valve
piping assy  from
compressor.
3. Remove  the compressor
mounting  bolts.
4. Carefully  remove  the
compressor  from chassis.