Brochure

SPECIFICATIONS
WallMaster Thru-the-wall Air Conditioners Brochure_2015 (1-15) Printed in USA
ENERGY STAR
®
models
HEATING PERFORMANCE: Change-over from heat pump operation to resistance
operation on models indicated is automatic at a preset outside ambient temperature
of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating perfor-
mance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the
electric heat starts, then operates with the fan to maintain indoor comfort. Below
43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Heat Pump heating information (shown in red) indicates heat pump heating performance. Electric Heat heating information (shown in red) indicates electric heat
strip performance. For Heat Pump electric heating performance refer to corresponding Electric Heat model.
LISTED
ROOM AIR CONDITIONERS
183H
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
As an
ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the
ENERGY STAR
®
guidelines for energy efciency.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity
cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
WallMaster
®
Model Number
Circuit
Rating
Breaker
or T-D Fuse
Plug
Face
(NEMA#)
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
WS08D10, WS10D10 and
WS12D10.
125V - 15A 5 - 15P 6
WS10D30, WS12D30 and
WS15D30.
250V - 15A 6 - 15P 6
WE10D33, WE12D33 and WE15D33.
WY09D33 and WY12D33.
250V - 20A 6 - 20P 6
Model
Carton Dimensions
INCHES
Height Wi d th Depth
WallMaster
®
WSE Sleeve 18" 27 1/4" 18"
Chassis 19 3/8" 30 5/8" 27 1/2"
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com
PLUG FACE/CIRCUIT RATING
Model Cooling Btu Heating Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Watts
Heating
Amps EER CEER
Estimated
Yearly
Energy
Cost COP
Moisture
Removal
Pints per
Hr.
Model
CFM
Net Wt
Lbs
Ship Wt
Lbs
Cooling only
WS08D10 8000 NA 115 6.4 769 NA NA 10.4 10.2 $69 1.8 250 93 97
WS10D10 9700 NA 115 8.0 990 NA NA 9.8 9.7 $89 2.4 260 103 107
WS10D30 10000/9800 NA 230/208 4.5/4.9 1020/1000 NA NA 9.8/9.8 9.7/9.7 $92 1.5 260 101 105
WS12D10 12000 NA 115 10.8 1224 NA NA 9.8 9.7 $110 3.5 295 112 116
WS12D30 12000/11700 NA 230/208 5.5/5.8 1224/1194 NA NA 9.8/9.8 9.7/9.7 $110 3.5 290 109 113
WS15D30 14500/14200 NA 230/208 7.0/7.5 1559/1527 NA NA 9.3/9.3 9.3/9.3 $140 4.8 290 119 123
Heat pumps
WY09D33 9000/9000 8100/7800 230/208 4.4/4.7 918/918 880/830 4.1/4.4 9.8/9.7 9.7/9.7 $83 2.70/2.75 2.5 260 103 107
WY12D33 11500/11300 9200/8800 230/208 5.5/5.8 1237/1215 1227/1158 5.5/5.8 9.3/9.3 9.3/9.3 $111 2.20/2.23 3.4 275 111 115
Cooling with electric heat
WE10D33 10000/9800 11000/9100 230/208 4.5/4.9 1020/1000 3550/2950 16.0/14.7 9.8/9.8 9.7/9.7 $92 1.5 260 104 108
WE12D33 12000/11700 11000/9100 230/208 5.5/5.8 1224/1194 3550/2950 16.0/14.7 9.8/9.8 9.7/9.7 $110 3.5 290 107 111
WE15D33 14500/14200 11000/9100 230/208 7.0/7.5 1559/1527 3550/2950 16.0/14.7 9.3/9.3 9.3/9.3 $140 4.8 290 119 123