Technical Specs

SPECIFICATIONS
BR_WM_2021 Printed in USA
ENERGY STAR
®
models
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com
HEATING PERFORMANCE: Change-over from heat pump operation to resistance
operation on models indicated is automatic at a preset outside ambient
temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does not
exceed the resistance heating capacity rating of the unit, the heating performance
will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the
electric heat starts, then operates with the fan to maintain indoor comfort. Below
43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Heat Pump heating information (shown in red) indicates heat pump heating performance. Electric Heat heating information (shown in red) indicates electric heat
strip performance. For Heat Pump electric heating performance refer to corresponding Electric Heat model.
LISTED
ROOM AIR CONDITIONERS
183H
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the
ENERGY STAR
®
guidelines for energy efciency.
EER is the unit’s Energy Efciency Ratio; CEER is the unit’s Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on a electricity cost of $.12 per kWh.
For more information, visit www.ftc.gov/energy.
Model
Circuit
Rating
Breaker
or T-D Fuse
Plug
Face
(NEMA#)
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
WCT08A10A, WCT10A10A and
WCT10A30A
125V - 15A 5 - 15P 6
WCT12A10A., WCT12A30A and
WCT16A30A.
250V - 15A 6 - 15P 6
WHT12A33A, WET10A33A and
WET12A33A. WET16A33A.
250V - 20A 6 - 20P 6
Model
Carton Dimensions
Height W i d t h Depth
WallMaster
®
WSE Sleeve 18" 27
1
/
4
" 18"
Chassis 19
3
/
8
" 30
5
/
8
" 27
1
/
2
"
PLUG FACE/ CIRCUIT RATING
Model UPC
Cooling
Btu
Heating
Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Watts
Heating
Amps EER CEER
Estimated
Yearly
Energy
Cost COP
Moisture
Removal
Pints
per Hr. CFM
Wt Lbs
Net/Ship
Cooling Only
WCT08A10A
724587436655
8000 115 7.0 748 10.7 10.6 $73 1.8 250 93/97
WCT10A10A
724587436662
10000 115 9.3 935 10.7 10.6 $92 2.4 250 103/107
WCT12A10A
724587436952
12000 115 11.1 1250 9.6 9.5 $122 3.8 295 101/105
WCT10A30A
724587436945
10000 230 4.4 935 10.7 10.6 $92 2.7 275 112/116
WCT12A30A
724587436969
12000 230 5.4 1250 9.6 9.5 $123 3.8 300 109/113
WCT16A30A
724587436976
15400 230 7.5 1638 9.4 9.3 $161 4.8 290 119/123
Cooling with Heat Pump
WHT12A33A 724587436983 11100 8900 230 5.5 1181 1087 5.0 9.4 9.3 $102 2.4 3.1 275 111/115
Cooling with Electric Heat
WET10A33A
724587436990
10000 11000 230 4.4 935 3550 16.0 10.7 10.6 $92 2.7 260 104/108
WET12A33A
724587437003
12000 11000 230 5.4 1250 3550 16.0 9.6 9.5 $123 3.8 290 107/111
WET16A33A
724587437010
15400 11000 230 7.5 1638 3550 16.0 9.4 9.3 $161 4.8 290 119/123