Thru-The-Wall Air Conditioners Brochure

SPECIFICATIONS
BRO_WM_2018 Printed in USA
ENERGY STAR
®
models
HEATING PERFORMANCE: Change-over from heat pump opera-
tion to resistance operation on models indicated is automatic at a
preset outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat
loss does not exceed the resistance heating capacity rating of the unit,
the heating performance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is
desired, an optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature)
and terminated at 43°F (outdoor coil temperature). During defrost,
the compressor stops and the electric heat starts, then operates
with the fan to maintain indoor comfort. Below 43°F, the unit re-
mains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately
50°F to prevent condensate from freezing inside drain pan.
Heat Pump heating information (shown in red) indicates heat pump heating performance. Electric Heat heating information (shown in red)
indicates electric heat strip performance. For Heat Pump electric heating performance refer to corresponding Electric Heat model.
LISTED
ROOM AIR CONDITIONERS
183H
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the
ENERGY STAR
®
guidelines for energy efficiency.
EER is the unit’s Energy Efciency Ratio; CEER is the units Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
WallMaster
®
Model Number
Circuit
Rating
Breaker
or T-D Fuse
Plug
Face
(NEMA#)
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
WS08D10A, WS10D10B and
WS12D10A.
125V - 15A 5 - 15P 6
WS10D30A, WS12D30A and
WS15D30A.
250V - 15A 6 - 15P 6
WE10D33, WE12D33 and
WE15D33A. WY12D33A.
250V - 20A 6 - 20P 6
Model
Carton Dimensions
Inches
Height Wid t h Depth
WallMaster
®
WSE Sleeve 18" 27 1/4" 18"
Chassis 19 3/8" 30 5/8" 27 1/2"
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com
PLUG FACE/CIRCUIT RATING
Model Cooling Btu Heating Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Watts
Heating
Amps EER CEER
Estimated
Yearly
Energy
Cost COP
Moisture
Removal
Pints
per Hr. CFM
Net Wt
Lbs
Ship Wt
Lbs
Cooling Only
WS08D10A 8000 115 6.3 748 10.7 10.6 $67 1.8 250 93 97
WS10D10B 9800 115 9.1 935 10.7 10.6 $83 2.4 250 103 107
WS10D30A 10000/9900 230/208 4.4/4.6 935/925 10.7/10.7 10.6/10.6 $84 2.7 260 101 105
WS12D10A 12000 115 10.8 1224 9.8 9.7 $110 3.5 295 112 116
WS12D30A 12000/11700 230/208 5.5/5.8 1224/1194 9.8/9.8 9.7/9.7 $110 3.5 290 109 113
WS15D30A 14500/14300 230/208 6.7/7.2 1543/1521 9.4/9.4 9.3/9.3 $140 4.8 290 119 123
Cooling with Heat Pump
WY12D33A 11300/11000 8900/8700 230/208 5.5/5.6 1215/1183 1119/1082 5.0/5.3 9.4/9.4 9.3/9.3 $102 2.3/2.3 3.4 275 111 115
Cooling with Electric Heat
WE10D33 10000/9800 11000/9100 230/208 4.5/4.9 1020/1000 3550/2950 16.0/14.7 9.8/9.8 9.7/9.7 $92 1.5 260 104 108
WE12D33 12000/11700 11000/9100 230/208 5.5/5.8 1224/1194 3550/2950 16.0/14.7 9.8/9.8 9.7/9.7 $110 3.5 290 107 111
WE15D33A 14500/14300 11000/9100 230/208 6.7/7.2 1543/1521 3550/2950 16.0/14.7 9.4/9.4 9.3/9.3 $140 4.8 290 119 123