no response, verify the following:
Please check whether the wire is correct.
Please check whether the baud rate, parity, stop bit and other configurations are correct.
The module runs in UART sleep wake-up mode, the wake-up code should be added.
The module is in AT command mode.
the default carriage return (\r\n), the carriage return (\r\n) should be canceled.
Switch to AT command mode
In transparent transmission mode, you can temporarily enter AT command mode by sending
a command sequence. At this time, if a valid command isn’t received within timeout
period(default 10s), module will automatically return to transparent transmission mode; if the
module needs to quickly return to transparent transmission mode, you can send AT + EXIT
command.
If module want to stay in AT command mode,send AT + ATMODE = 0 to activate it. If the
module needs to be in AT command mode after restart or reset, execute AT + SAVE to
save parameters. See the following example:
+++
OK
AT+ATMODE=0
OK
AT+SAVE
OK
5.2 Network Configuration
Before using the module, please confirm the operating frequency band and working channel.
Ensure that the upstream channel of the module exactly matches the receiving channel of
the gateway before conducting subsequent activation operations and data sending and
receiving .
For AU915, US915 and other frequency bands, the channels of module can be configured
through the channel mask command (usually 8 channels are a group), such as selecting