User's Manual

Table Of Contents
WSL05-A0_User_Manual
Page
37
/
58
same as those of the server.
Set to ABP activation mode.
Save parameters.
After the configuration is complete, the module is in an activated state on reset (that can
send data to the server).
View an example of activation configuration for ABP mode:
AT+DEVADDR=1
OK
AT+NWKSKEY=1234567890ABCDEF1234567890ABCDEF
OK
AT+APPSKEY=00112233445566778899AABBCCDDEEFF
OK
AT+JOINMODE=1
OK
AT+SAVE
OK
AT+RESET
OK
5.4
Join Network
In OTAA mode, to connect module to LoRaWAN server, the Join process is required. Module
provides two trigger modes for network access request:
Automatic network access
Manual access
After module is powered on or reset, it will determine whether the join process is needed
according to different configurations or conditions. It is recommended to set this parameter
before activating the module.
There is no Join process in ABP mode.