Specification

Specifications
subject to change.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FGGF3058R 10/15 © 2015 Electrolux Home Products, Inc.
Freestanding Ranges
FGGF3058R F/ W/ B 30" Gas
Freestanding Range Specifications
Product Shipping Weight (approx.) – 205 Lbs.
Voltage Rating – 120V / 60 Hz / 5 Amps
Amps @ 120 Volts = 5 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
Do not install range beneath any downward-blowing, overhead vent
hood or air curtain.
Range ships with 3/4" factory regulator.
Range is LP Gas convertible. (Optional LP Gas conversion
kit available.)
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
Minimum clearance required (from edge of rangetop to nearest
combustible wall on either side of range above 36" height) is based
on largest burner output rating on cooking surface.
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
LP Gas Conversion Kit – (PN # GRLP4).
Griddle – Included
30" min.
13"
max.
25"
Minimum
clearance (A)
required to
nearest
combustible
wall on
either side
of range
above 36"
height
30"
C
L
36"
stand.
Wall
15"
11
1
/2"
Recommended area for through-the-floor
connection of pipe stub and shutoff valve
8"
Recommended area for 120V outlet on rear of
wall and area for through-the-wall connection
of pipe stub and shutoff valve
23"
18"
min.
24"
10
1
/2"
2"
18"
min.
Front
29
7
/8"
48
1
/2"
max.
46
5
/8"
Gas inlet location
(right bottom rear*)
Power cord location
(left bottom rear*)
*when viewed from front
Side
25
3
/
4
"
29
1
/4"
30" Gas Freestanding Ranges
Frigidaire Gallery
30"
min.*
Clearance (A)
Based on Largest Minimum
Burner Output Rating Clearance
on Cooking Surface Required
9,500 BTU or less 2"
10,000
-
16,999 BTU 3"
17,000 BTU or greater 5"
* Min. distance from cooking surface
to underside of overhead cabinetry
36"
(Adjustable
to
±
1
/8")
Note: Overall
product dimensions
are model specific
and may vary slightly
from illustration. Refer
to model’s product
specifications for
actual dimensions.