Installation Guide
This product requires a three-prong grounded
outlet. The installer must perform a ground
continuity check on the power outlet box before
beginning the installation to ensure that the outlet
box is properly grounded. If not properly grounded,
or if the outlet box does not meet electrical
requirements noted
(under ELECTRICAL REQUIREMENTS), a qualified
electrician should be employed to correct any
deficiencies.
CAUTION: For personal
safety, remove house
fuse or open circuit
breaker before
beginning installation to
avoid severe or fatal
shock injury.
CAUTION: For personal safety, the mounting surface
must be capable of supporting the cabinet load, in
addition to the added weight of this 63–85 pound
(28.5–38.5 kg) product, plus additional oven loads of
up to 50 pounds (22.7 kg) or a total weight of
113–135 pounds (51.3–61.2 kg).
CAUTION: For personal safety, this product cannot be
installed in cabinet arrangements such as an island or
a peninsula. It must be mounted to BOTH a top
cabinet AND a wall.
NOTE: For easier installation and personal safety, it is
recommended that two people install this product.
IMPORTANT – PLEASE READ CAREFULLY. FOR
PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED TO AVOID SEVERE OR
FATAL SHOCK.
T
h
e power cord of this
appliance is
equipped
with a three-prong
(grounding) plug which
mates with a standard
three-prong
(grounding) wall
receptacle to minimize
the possibility of electric
shock hazard from this
appliance.
Y
ou should have the wall receptacle and circuit
checked by a qualified electrician to make sure
the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is very important to have it
replaced with a properly grounded three-prong
wall receptacle, installed by a qualified electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT,
DEFORM OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT USE WITH AN
EXTENSION CORD.
IMPORTANT SAFETY INSTRUCTIONS
Ensu
r
e proper
ground exists
be
f
ore use
Installation Instructions
EL
ECTRICAL
REQUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 15 amps
and 1.6 kilowatts. This product must be connected
to a seperate and dedicated supply circuit of the
proper voltage and frequency. Wire size must
conform to the requirements of the National
Electrical Code or the prevailing local code for this
kilowatt rating. The power supply cord and plug
should be brought to a seperate and dedicated 15- to
20- ampere branch circuit single grounded outlet.
The outlet box should be located in the cabinet
above the microwave oven. The outler box and
supply circuit should be installed by a qualifed
electrician and conform to the National Electrical
Code or the prevailing local code.
EN-3