Installation guide

7
INSTALLATION REQUIREMENTS
Number of 90° turns
MAXIMUM LENGTH
of 4” (102 mm) Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
4” (10.2 cm) louvered 2.5” (6.35 cm)
0 56 ft. (17 m) 42 ft. (13 m)
1 48 ft. (14.5 m) 34 ft. (10.5 m)
2 40 ft. (12 m) 26 ft. (8 m)
3 32 ft. (9.5 m) 18 ft. (5.5 m)
The dryer must be connected to an exhaust
outdoors. Prior to installing your new
dryer, inspect the outdoor exhaust opening
and remove any accumulation of lint around
the outdoor exhaust opening and in the
surrounding area.
WARNING
FIRE HAZARD
A clothes dryer must be exhausted outdoors.
DO NOT exhaust dryer into a chimney, a
wall, a ceiling, an attic, a crawl space or
any concealed space of a building. A clothes
dryer produces combustible lint. If the dryer
is not exhausted outdoors, some ne lint
will be expelled into the laundry area. An
accumulation of lint in any area of the home
can create a health and re hazard.
WARNING
FIRE HAZARD
DO NOT allow combustible materials
(for example: clothing, draperies/
curtains, paper) to come in contact with
exhaust system. The dryer MUST NOT
be exhausted into a chimney, a wall,
a ceiling, or any concealed space of
a building which can accumulate lint,
resulting in a re hazard.
DO NOT screen the exhaust ends of the
vent system, or use any screws, rivets
or other fasteners that extend into the
duct to assemble the exhaust system.
Lint can become caught in the screen, on
the screws or rivets, clogging the duct
work and creating a re hazard as well as
increasing drying times. Use an approved
vent hood to terminate the duct outdoors,
and seal all joints with metal foil duct
tape. All male duct pipe ttings MUST be
installed downstream with the ow of air.
WARNING
FIRE HAZARD
Exceeding the length of duct pipe or
number of elbows allowed in the “MAXIMUM
LENGTH” charts can cause an accumulation
of lint in the exhaust system. Plugging the
system could create a re hazard, as well as
increase drying times.
Correct
Incorrect
WARNING
FIRE HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
DO NOT install a booster fan in the exhaust
duct.
Install ALL clothes dryers in accordance with
the installation instructions in this manual.