http://biz.LGservice.com Dehumidifier SERVICE MANUAL MODELS: DH300EY5/DH305Y5/DH300MY5 LD40Y5/DH400MY5 DH404EY5/DH400EY5/LD40EY5 DH504ELY5/LD50ELY5 LD65ELY5 CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORIZED SERVICE.
CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS ...........................................................................................................................3 1.2 FEATURES AND DIMENSIONS ................................................................................................................3 1.2.1 FEATURES........................................................................................................................................3 1.2.2 DIMENSIONS ................................
1. PREFACE This Service Manual provides various service information, including the mechanical and electrical parts. This dehumidifier was manufactured and assembled under the strict quality control procedures. The refrigerant is charged at the factory. Be sure to read the safety precaution prior to servicing the unit. 1.1 SAFETY PRECAUTIONS • Disconnect the power supply before servicing or replacing any component. • Do not cut off the grounding prong or alter the plug in any manner. 1.
1.3 MODEL NAMES MODEL NAME CAPACITY (Pints/24hrs) MECHANICAL TYPE CONTROL PANEL ELECTRONIC TYPE 30 40 50 65 DH305Y5, DH300MY5 DH400MY5,LD40Y5 - - DH300EY5 DH404Y5 DH400EY5,LD40EY5 DH504ELY5 LD50ELY5 LD65ELY5 1.4 SPECIFICATIONS MODELS ITEMS POWER SUPPLY(Phase,V,Hz) INPUT(W) RUNNING CURRENT(A) ENERGY FACTOR(L/kw.h) REFRIGERANT REFRIGERANT CHARGE, oz(g) OPEN CLOSE THERMISTOR SOLENOID VALVE* COMPRESSOR MODEL No.
1.5 CONTROL TYPE 1.5.1 Mechanical type 4 3 5 6 7 2 Auto Shut-Off Humidity Control • When you first use the dehumidifier, turn the humidity control to 5 or 6. If you still have moisture, turn the humidity control to a higher setting. MAX is the highest setting. • When excess moisture and dampness odors are gone, adjust the control to a lower setting. Use the dehumidifier as long as excess moisture is present.
1.6 HOW TO OPERATE DEHUMIDIFIER 1.6.1 HOW DOES THE DEHUMIDIFIER WORK? Motor Condenser Fan Evaporator Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through the bucket into a hose and drain). Dry, clean air is drawn over the condenser where it is actually heated several degrees and discharged out the rear grill into the room.
1.6.5 HUMIDITY CONTROLLER 5(42%) 42% R.H 1.6.5.1 Mechanical Type The humidity control can be set anywhere between Off and Max for normal operation. If you need more dehumidification, turn the Humidity Control toward Max. If you need less dehumidification, turn the Humidity Control toward Off. The relative humidity range is from 20% to 80%. (See Figure 6) Turn the Humidity Control to Off to stop the unit manually. 40% 4(50%) 6(35%) 3(60%) 7(30%) 2(70%) 8(25%) 9(20%) 1(80%) Off DEAD DIAL Max.
2. CIRCUIT DIAGRAM • MODEL : DH305Y5, DH300MY5 PART NO. DESCRIPTION NO.
• MODEL : DH300EY5 PART NO. DESCRIPTION NO.
• MODEL : DH400MY5/LD40Y5 NO. PART NO.
• MODEL : DH404EY5/DH400EY5/LD40EY5 PART NO. DESCRIPTION NO.
• MODEL : DH504ELY5/LD50ELY5/LD65ELY5 DESCRIPTION NO. PART NO. DH504ELY5/LD50ELY5 LD65ELY5 6411A20001Z Q'TY REPER SET MARKS 1 S 4681A20040K 1 S 0CZZA20005J 0CZZA20005J 1 S COMPRESSOR (ROTARY), SET 2520UCBA010 2520UCBA007 1 S 5 OLP.
3. DISASSEMBLY INSTRUCTIONS 3.1 MECHANICAL PARTS 3.1.1 BUCKET AND AIR FILTER 1. Turn the Humidity Control off(Mechanical type) or press the power button off. (Electronic type) 2. Disconnect the power supply. 3. Remove the bucket. (See Figure 9) 4. Pull out the air filter. (See Figure 10) Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 3.1.2 FRONT CASE AND REAR GRILLE 1. Remove 2 screws which fasten the front grille. 2. Pull the front grille forward and upward. (See Figure 11) 3.
3.2 CONTROL PARTS 3.2.1 POWER CORD ASSEMBLY 1. After opening the control box, remove the screw that holds the ground wire. (See Figure 15) 2. Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box. Figure 15 3.2.2 SENSOR ASSEMBLY 1. Disconnect the sensor assembly from the PWB(PCB) ASSEMBLY, MAIN. 2. Remove the screw which fastens the humidity sensor. (See Figure 16) 3. Remove the thermistor from the holder. (See Figure 16) 4.
3.2.6 COIL ASSEMBLY, SOLENOID (DH504ELY5, LD50ELY5, LD65ELY5) 1. Disconnect the housing of the COIL ASSEMBLY, SOLENOID from the PCB(PWB) ASSEMBLY, MAIN. 2. Remove the screw that fastens the COIL ASSEMBLY, SOLENOID. (See Figure 19) 3. Pull it out upwards. Figure 19 3.2.7 CONTROL PANEL 3.2.6.1 CONTROL PANEL - Mechanical Type (DH305Y5/DH300MY5/DH400MY5/LD40Y5) 1. Disconnect housing and all leads of the rocker switch, SWITCH ASSEMBLY, ROTARY and PWB(PCB) ASSEMBLY, DISPLAY from PWB(PCB) ASSEMBLY, MAIN (3.1.
3.2.8 FAN AND MOTOR 1. Turn the nut left and full out the Fan by hands carefully. 2. Remove 2 screws that fasten Heat Exchange. 3. Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 22) 4. Unfasten 3 screws that secure the Motor and earth wire. (See Figure 23) 5. Remove the Motor. Figure 22 Figure 23 3.2.9 SHROUD AND DRAIN PAN 1. Discharge the refrigerant by using a refrigerant Recovery System. 2.
3.3 REFRIGERATING CYCLE 3.3.1 CONDENSER, EVAPORATOR AND CAPILLARY TUBE 1. Remove the insulation on the Heater/Evaporator (H/E) assembly 2. Pierce the pinch-off tube to discharge the refrigerant, using a refrigerant recovery system. 3. After discharging the refrigerant completely, remove 2 screws between the housing assembly and the H/E. (See Figure 26) 4. Lift the H/E and open the H/E around 45 degree counterclockwise carefully. 5.
3.4 HOW TO REPLACE THE REFRIGERATION SYSTEM 1. When replacing a refrigeration component, be sure to discharge the refrigerant system by using a refrigerant recovery system. 2. After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes. 3. Solder service valves into the pinch-off tube ports, leaving the valves open. 4. Solder the pinch-off tubes with service valves. 5.
Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment. pinch-off tool capable of making a vapor-proof seal, leak detector, tubing cutter, hand tools to remove components, service valve.
4. TROUBLESHOOTING GUIDE CONDITION 1. Dehumidifier does not start. (Both compressor and fan motor do not operate.) CAUSE REMEDY No power Check power supply at outlet. Correct if none. Poor plug contact at outlet. Install plug properly or replace it. Bucket is full. If Auto Shut Off lights, empty the bucket and replace properly. Humidity control is at Off position Turn the humidity control switch toward Max. Wire disconnected or loose Connect wire.
CONDITION 5. Noisy operating 6. Water drips 7. Compressor cycles on overload protector. (OLP) CAUSE REMEDY Fan If cracked, out of balance, or partially missing, replace it Loose foreign material inside the housing. Remove it. Tube hits frame. Adjust tubing routine carefully. Fan blade hits frame Check Motor Mount. If loose, tighten it. Internal compressor noise. Replace compressor. Loose set screws Tighten them.
5.
• MODEL: DH300EY5 W0CZZ-2 149980 349600 554030 354210 268711-2 359012 264110 249950 346811 435300 165010 131400 135312 238310 235512 268711-1 436500 352113 35211A 152302 266010 552111 752140 330870 567502 130410 554160 148391 144410 550140 —23—
• MODEL: DH400MY5/LD40Y5 149980 W0CZZ-2 349600 554030 354210 359012 268711-2 249950 346811 435300 264110 131400 165010 135312 149410 266002 238310 EN ER GY 268711-1 STA R Sh Au t ut o -O ff O ff Hu m id ity M ax Co nt ro l Hi Fa nS pe Lo ed gh w 436500 266003 352113 235512 35211A 152302 266010 552111 752140 330870 567502 130410 554160 148391 144410 550140 —24—
• MODEL: DH404EY5/DH400EY5/LD40EY5 149980 W0CZZ-2 349600 554030 354210 359012 268711-2 249950 346811 435300 264110 131400 165010 135312 238310 235512 268711-1 436500 352113 35211A 152302 266010 552111 752140 330870 567502 130410 554160 148391 144410 550140 —25—
• MODEL: DH504ELY5/LD50ELY5 149980 W0CZZ-2 349600 554030 354210 359012 268711-2 346811 249950 435300 264110 131400 165010 135312 238310 235512 268711-1 436500 552204 35211A 152302 266010 352113 752140 330870 567502 130410 554160 148391 144410 550140 —26—
• MODEL: LD65ELY5 149980 W0CZZ-2 349600 554030 354210 359012 268711-2 346811 249950 435300 264110 131400 165010 135312 238310 235512 268711-1 436500 552204 35211A 152302 266010 352113 752140 330870 130410 148391 144410 567502 554160 550140 —27—
6. REPLACEMENT PARTS LIST • MODEL: DH305Y5/DH300MY5 PART NO. LOCATION NO.
• MODEL: DH300EY5 PART NO. LOCATION NO.
• MODEL: DH400MY5/LD40Y5 PART NO. LOCATION NO.
• MODEL: DH404E Y5/DH400EY5/LD40EY5 PART NO. LOCATION NO.
• MODEL: DH504ELY5/LD50ELY5 PART NO. LOCATION NO.
• MODEL: LD65ELY5 PART NO. LOCATION NO.
P/No : 3828A31001 January, 2005 Printed in China