Assembly Instruction

1
137066200 B (0808)
Installation Instructions
Natural Gas Dyer to LP Conversion Kit
WARNING
WARNING
This conversion kit shall be installed by a qualifi ed service agency
in accordance with the manufacturer’s instructions and all appli-
cable codes and requirements of the authority having jurisdiction.
The information in these instructions must be followed to mini-
mize the risk of fi re or explosion or to prevent property damage,
personal injury or death. The qualifi ed service agency is respon-
sible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appli-
ance is checked as specifi ed in the manufacturer’s instructions
supplied with the kit.
Failure to comply with the following proper instructions and use of correct conversion kit can
result in fi re, explosion, serious bodily injury and/or property damage.
Conversion is at the risk of
and the responsibility of the person making the conversion and shall be made by a QUALIFIED SER-
VICE TECHNICIAN ONLY. USE ONLY THE CONVERSION KIT SPECIFIED IN THE PARTS CATALOG
FOR THE MODEL NUMBER OF THE DRYER BEING CONVERTED.
IMPORTANT
This kit was designed to be used with bottled gas (tanks). The gas line must be equipped with
a gas pressure regulator that provides gas between 8 inches (20 cm) water column maximum
and 11 inches (28 cm) water column minimum at the connection to the dryer.
This kit is approved for use on dryers manufactured on or after July 1, 2008, having burners
with a gas valve showing part no. 13118070 or 145493-000.
If installing this conversion kit on valve no. 13118070, input rating will be 22,000 BTU’s/hour. If
installing this conversion kit on valve no. 145493-000, input rating will be 20,000 BTU’s/hour.
BTU rating refers to heat input at sea level. For operation at elevations above 2,000 feet, the
BTU input rating should be reduced at the rate of 4 percent for each 1,000 feet above sea level.
Observe all local codes and American National Standard National Fuel Gas Code ANSI Z
223.1-1988. Contact the tank gas dealer for any questions about installation.
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CSA B149.1, INSTALLATION CODE.
Refer to the product Installation Instructions for gas supply line connections to the dryer.
Kit Components:
Stainless steel burner tube1.
Screw, #8 (18x.375)2.
Converted rating plate (English)3.
Converted rating plate (French)
Adjustable shutter4.
Alignment collar5.
Blocking pin6.
LP orifi ce (stamped “55”)7.
Control conversion label8.
55
55
55
55
55
55
55
55
Cette sécheuse a été convertie le
année mois jour
pour fonctionner au gaz LP à l’aide
de la trousse no PCK4100
par
(nom et adresse de l’organisme qui
a effectué la conversion), qui
accepte l’entière resonsabilité de la
qualité de la conversion.
Pression à la tubulure
d’alimentation (”wc):
7” - 10”
Injecteur numéro: 55
Debit calorifique (Btu/hr):
22,000 (6.45 kWh)
137070401 0807
This dryer was field converted on
day
month
year
to LP gas with Kit No.
by
(name and address of organization
making this conversion), who
accepts the responibility for the
correctness of this conversion.
Manifold pressure (”wc):
7” - 10”
Orifice size: 55
Input rating (Btu/hr):
was
f
ield converted o
n
mont
h
year
wi
t
h
Ki
t
N
o.
address of organization
Ori
fic
e s
: 5
5
Inp
ut rat
(B
tu
/
hr)
:
This control has
been converted for
use with LP gas.
Cette sécheuse a été
convertie pour
fonctionner au gaz LP.
137070500 0807

Summary of content (16 pages)