Keep Well This Manual. Read Rules for Safe Operation and Instructions Carefully.
1. ELECTRICAL SAFETY RULES .............................................................. 2. UNIT PARTS IDENTIFICATION 3. POINTS FOR ATTENTION 4. OPERATION OPERATION 5. CAREAND 6. WINDOW .............................................................. WHEN OPERATING .................................... 1 2 3 PANEL(Cooling only type) ..................................................... 4 INSTRUCTION .................................................................. 4 ...............................
All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician. Never insert your fingers or any foreign objects into the air outlet. Take special care to warn children of these dangers. To avoid the possibility of personal injury, be sure to disconnect power to the unit before installing and/or servicing and/or cleaning.
\ \ 1. Front panel 2. Air filter 3. Frame 4. Cabinet \ 5. Air inlet grille (outdoor side) 6. Air outlet grille 7. Operation panel 8. Power supply and plug Fig.
1. During the course of operating, if you have turned off the unit or changed operation mode from COOLING MODE to FAN MODE, be sure to keep that state for at least three minutes before switching to COOLING MODE again. 2. Attaching the Air Filter Before starting the air conditioner operation, make sure that the air filter is well attached. If the unit has not been used for a long time, it is recommended to clean the air filter before your using the unit.
THERMOSTAT 5 6 SELECTOR OFF 7 4 8 u_ 2 10 k_ _o,, CC_L I 11 WAITTHREEMINUTES BEFORE RESTARTING Fig. 2 1. Pull the top of the operation cover to open it. 2. Close the operation cover and press the top until it snaps into the locked position. Don't press or swing the opened operation Fig.
imlmmr ttm To set desired cooling temperature, simply rotate the SELECTOR knob to the appropriate setting. "HIGH FAN" will circulate the air at a maximum SELECTOR speed without cooling. "MED FAN" will circulate the air at a middle speed without cooling. OFF "HIGH FAN" provides cooling automatically with maximum air circulation. H_H __W "MED COOL" provides cooling automatically with middle air circulation. LOW "LOW COOL" provides cooling automatically with minimum air circulation.
During the cooling operation of the unit, when the thermostat knob is rotated counterclockwise, allow at least three minutes before turning back the knob to the "COOLER" direction. overload of the unit. Otherwise the fuse may blow due to an Horizontal air flow adjustment (manually) Move the "T" shaped handle left or right to adjust horizontal air flow. Fig. 4 Vertical air flow adjustment (manually) To adjust vertical air flow direction, adjust any one of the horizontal louver blades. Fig.
This is usually kept in the closed position and use only when clearing smoke and/or odors from the room. When the ventilation switch is pushed to "CLOSE", the fresh air ventilation is closed; when the ventilation switch is pushed to "VENT", the fresh air ventilation is opened. • Keeping the fresh air ventilation opened for a long time will reduce the cooling effeciency. To avoid the possibility of personal injury, be sure to disconnect power to the unit before servicing and/or cleaning.
If the air filter becomes clogged with dust, air flow is obstructed and reduces cooling efficiency. The air filter should be cleaned every two weeks. Fig. 7 1. Removal of Air Filter 1) Press "PUSH" on the bottom corners of the inlet grill. See Fig. 7 2) Pull the air filter down to remove. 2, Cleaning of Air Filter 1) Remove the dust clogged in the filter by tapping it or vacuum clean it. 2) Wash the filter well with lukewarm water or a neutral cleaning agent. 3.
• Dust may accumulate on the front panel, use soft wet cloth with a neutral cleaning agent to wipe it. • Never use water over 50°C, alcohol, gasoline, acid, solvent or brush to clean the front panel as this will damage the surface of the part. OPERATING _f_____-; ,. ,' / THE _ANA_ONE z 1. Operating the fan alone for half a day See to dry out the inside of the unit. 2. Turn off power and remove plug from wall outlet. WHEN OPERATING 9 POINTS FOR A-FFENTION on page 3.
6. Top mounting seal strip \ \ 5. Window rail \ 7. Foam top window j4. 3. Accordion sash seat gasket Top mounting rail panel 13. Connection 1. Sill suppo_ 2. Bottom 8. Type A (4) mounting rail 9. Type B (9) 10. Type C (8) 11. Nut (2)@ 12. Bolt (2)_ Fig.
A i=o, t,'-- "H'l 5000 and 6000 BTU models • These instructions are for a standard double-hung window. You will need to modify them for other types of windows. • The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions 14" rain, below. 22" to 30" (With accordion panels) • All supporting parts must be secured to firm wood, masonry or metal.
B. Remove the 2 screws at the bottom, and remove the frame from the cabinet. Note: No need to remove the selector and thermostat knobs. C. Remove the 2 screws on each side of the case. Keep these for later use. D. Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. \ % Fig. 11 Fig. 12 Fig. 13 CAUTION! • Besureto removethe foamsurroundingthe compressorwheninstalling_ • If not, itwouldharmtheoperationof thecompressor.(See Fig.13) J J J/ A.
D. Install the Accordion panels (_ Attach the two Connection Bar to the case. Connect the shutter with the Connection Bar. Shu_er Fig. 19 Fig. 18 (_ Insert the shutters into its frame bar. Clip the shutters onto the frame bars And install the upper and lower frame bars. Fig. 20 ., with the clips. Fig. 21 Lower Frame Bar = _ = = o o A. Open the window and mark the centerline of the window stool. B.
D. Loosely assemble the sill supports. Indoor Outdoor \Nut Fig. 23 E. Select the position that will place the sill supports near the outermost point on the sill. Attach the sill supports to the case track hole in relation to the selected position using 4 type C screws in each supports. Fig. 24 F. Adjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside. Use a level; about 1/3" will be the correct case slant to the outside. G.
I= • _e el = I I = The installation process is the reverse of the removal process on page 11 and 12. See Fig 11. Fig. 28 Save time and money! Review the chart below first and you may not need to call for service. Possible Causes Air conditioner The air conditioner is does not start unplugged, What • To Do Make sure the air conditioner plug is pushed completely into the outlet.
Possible Air conditioner does not cool as it should Causes What To Do Airflow is restricted. • The temp control may • On models with touch pads: In COOL mode, • press the DECREASEYpad. On modes with control knobs, turn the not be set correctly, Make sure there are no curtains, blinds or fumiture blocking the front of the air conditione_ temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Operoting Instructions section.
CS45-U 2200019260