USE & CARE MANUAL THISAIR STANDARD CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY POWER SUPPLY CORD WITHATEST-RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER MULTI-STEP SPEED ELECTRONIC CONTROLS P/N819042060-01
ROOM AIR CONDITIONER Your product is protected WARRANTY by this warranty Yourappliance is warranted by Electrolux. Electroluxhas authorized FrigidaireConsumer Services andtheir authorized servicersto perform service under this warranty. Electrolux authorizes no one else to change or add to any of these obligations under this warranty. Any obligations for service and parts under this warranty must be performed by Frigidaire Consumer Services or an authorized Frigidaire servicer.
Product Registration Record Your Modeland Serial Numbers Record in thespace provided belowthe model andserial numbers. plate is Iocatedon the outsideof the interior bulkhead left side. Onall models, theserial Model Number Serial Number Register Your Product The self-addressed PRODUCT REGISTRATION signed and returnedto the FrigidaireCompany. Contents NOTE: This USE & CARE MANUAL provides specific operating instructions for your model.
Read all instructions Important Safety Instructions The power supplycord with this air conditioner contains a current detection device designed to reduce the risk offire. Please referto the section 'Operation of Current Device'for details. Intheeventthatthe power supply cord is damaged, itcannot be repaired it must be replaced with a cord from the Product Manufacturer. Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
To reduce the risk of fire, electric shock, orinjury to persons, IMPORTANTSAFETY INSTRUCTIONS before operating thisappliance. Operation Device of Current read the i he power supplycord contains acurrent device thatsenses damage tothe power cord. To test your powersupply cord dothe following: 1. PlugintheAirConditioner. 2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. Youwill notice aclick as theRESET button pops out. 3. Press theRESET button.
Air Conditioner Features NOTE: The following instructions represent theControl instructions can beused for theRernote Control. Panel, thesarne (continued) YOU WILL SEE: TO TURN UNiT ON: j. DO THIS: ] PRESS ON/ OFF PAD TO CHANGE SETTING: YOU WILL SEE: TEMPERATURE @ DO THIS: PRESS TO RAISE PRESS TO LOWER TOAD JUST FAN SPEEDS: NOTE: Tap or hold either up( & ) or down ( _ ) button until the desired temperature is seen on the display.
Air Conditioner Features (continued) T_0_O USE AUTO COOL DO THIS: PRESSAUTO COOL TO OPERATE YOU FEATURE: WILLSEE: NOTE: Fan starts at High Speed and adjusts to a slower speed as the room temperature dictates, For example if the room does not get too warm, it will stay at the slowest speed, If the room temperature rises quickly, such as a door being opened, it will automatically go to the highest speed, The fan speeds will re-adjust back to the slowest speed as the room returns to the original set
Air Conditioner Features (continued) TIMER: BELAY STOP/START FEATURE: YOU WILL SEE: _LIGHT THEN DO THIS: PRESS UP(_)OR DOWN (v) BUTTON DO THIS: PRESSTIMER BUTTON SLEEP FEATURE: DO THIS: PRESS SLEEP BUTTON CHECK FILTER FEATURE: ON NOTE: For Delay Stop, the unit must be in the ON position. NOTE: For Delay Start, the unit must be in the OFF position. To adjust timer setting, tapor hold theUP arrow(A ) orthe DOWN arrow(_ ) to change delay timer at .
Air Conditioner Features (continued) HEATING FEATURE YOU WILL SEE: on some models): LIGHT DO THIS: PRESS MODE BUTTON SELECT HEAT CLEAN AIRFEATURE(0n NOTE: This feature can be Timer, or Sleep Modes. When while heat is needed. The anywhere between 60°F(15°C) is satisfied, the fan will cycle air. YOU some models): used with any combination of FAN Speeds, in the Heat Mode, the fan will run continuously temperature will automatically be maintained and 90°F(32°C).
Air Conditioner Features (continued) YOU WILL SEE: TO TURN UNiT OFF: ® DO THIS: PRESS ON/ OFF BUTTON ADDITIONAL Now that you have familiar with. mastered the operating procedure, THINGS YOU SHOULD herearemorefeaturesinyourcontrolthatyoushould • The"Cool" circuit has an automatic3minutetimedelayedstartiftheunitis turned off and overheating of the compressor and possible circuit breaker tripping. The fan will continue to .
Care and Cleaning Air Filter Clean your air conditioner sure to unplugthe unit hazards: occasionally beforecleaning to keep it looking to preventshock new. Be or fire Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation offroston the cooling coils. • Open the front panel. • Grasp the filterby the centerand pull upand out.
I I Avoid Service Checklist OCCURRENCE Air Before calling forservice, review this list. It may save you timeand includes common occurrences that are not the result of defective materials in thisappliance SOLUTION conditionerwill notoperate. Wall plugdisconnected. Current device House circuit tripped. fuse blown breaker. Control is OFR Unit turned Push plugfirmly Preset RESET or circuit breaker Turn control off and thenon into walloutlet. button. tripped. On andset too quickly.