Installation Instructions

or 4B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions . For existing installations ONLY -
Refer to Fig. 13).
1. Follow the manufacturer’s installation instructions supplied with the strain
relief and install (Also see Figs. 9, 10 & 11).
2. Insert the end connectors for Line 1, Line 2 and Neutral and tighten securely
to the terminal block (See Fig. 13).
IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block. Electrical
failure or loss of electrical connection may occur if these 3 nuts are loosened
or removed.
3. Make sure all connections are tightened securely and replace the rear
access cover (See Fig. 9).
Grounding Instructions (3-Wire Connections only): A ground strap is
installed on this range which connects the center terminal of the terminal block
(Neutral) to the range chassis. The ground strap is connected to the range by
the center, lowest screw (See Fig. 13). The ground strap must not be removed
unless National, State or Local Codes do not permit use of a ground strap.
NOTE: If the ground strap is removed for any reason, a separate ground wire
must be connected to the separate ground screw attached to the range chassis
and to an adequate ground source.
NOTE: Non-terminated eld wire compression connections must be set at
22 in./lbs. or greater. Always use 10 gauge wire or larger.
Fig. 13
4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.
3 - Wire Permanent Connection - follow Steps 1,2 & 5 below.
4 - Wire Permanent Connection - follow Steps 1 thru 5 below.
Before wiring the range, review the suggested power source location drawings in
Fig. 3. If connecting to a 4-Wire electrical system (new branch-circuit or mobile
home requires 4-Wire connection):
1. (3 & 4 - Wire Permanent Connections) Follow the manufacturer’s
installation instructions supplied with the strain relief and install.
2. (3 & 4 - Wire Permanent Connections) Strip insulation away from the ends
of the permanent wiring for Line 1, Line 2, Neutral (also strip ground wire on
4-Wire Connections). Tighten all 3 wire leads to the terminal block (Follow
wire locations shown in Fig. 14).
IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block. Electrical
failure or loss of electrical connection may occur if these 3 nuts are loosened
or removed. NOTE: For 3-Wire Permanent Connections skip Steps 3 & 4
and continue with Step 5.
3. (4-Wire Permanent Connection ONLY) Disconnect the ground strap.
Remove the factory installed ground screw & plate to release the factory
installed copper ground strap from frame of the appliance. Cut and discard
the copper strap from the terminal block. KEEP the ground screw, ground
plate and go to Step 4.
4. (4-Wire Permanent Connection ONLY) Connect the ground wire lead
(Green) to the frame of the appliance using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame where
the ground screw was originally installed.
5. (3 & 4 - Wire Permanent Connections) Make sure all connections are
tightened securely and replace the rear access cover (See Fig. 9).
Fig. 14
5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION.
Be sure to provide all the adequate clearances and dimensions shown in Figs. 1,
2 & 3 before moving appliance into nal location.
Carefully slide range into nal position while inserting rear leveling leg into and
FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7). Make sure the power
cord folds into the remaining open oor area behind the range Warmer or storage
drawer. Be sure to check the level of the range.
Fig. 15
4
INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE
Note: Non-terminated field wire compression
connections must be set at approximately 22in./lbs.
Always use 10 ga. wire or larger.
Serial plate is located on the lower right front frame
of the appliance. Alternate location may be under
cooktop.
Serial Plate Locations:
NOTE: Internal
white wire not
present on all
models.