Specification

USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FFED3026T 07/17
© 2017 Electrolux Home Products, Inc.
INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 185 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz, fused on
both sides of line with ground. (If local code permits, range may be connected
by hard-wiring or by means of power supply cord kit.)
Connected Load (kW Rating) @ 240 / 208 Volts = 11.8 / 8.9 kW
Amps @ 240 / 208 Volts = 33 /32.5 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Make sure wall coverings around range can withstand heat generated by range.
Linoleum or any other synthetic floor covering located beneath range, must
be capable of withstanding minimum heat of 90° F above room temperature
without shrinking, warping or discoloring. Insulating pad or 1/4"-thick plywood
required between range and a carpeted floor.
When installing optional Backguard Kit, cutout depth of 21-3/4" minimum / 
22-1/8" maximum needs increased to 24".
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets installed
to either side of appliance must be no less than maximum width of appliance.
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than 1/4"
flame-retardant millboard covered with not less than No. 28 MSG sheet steel,
0.015" stainless steel, 0.024" aluminum or 0.020" copper. Allow 30" minimum
clearance when cabinet is unprotected.
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
COUNTERTOP PREPARATION
Rangetop’s side flanges overlap countertop cutout edges — for detailed
preparation instructions, refer to product installation guide on the web.
Flat Square-Finish Countertops – require no preparation since rangetop’s
flange lays directly on countertop edge.
Formed Front-Edged Countertops – require front molded edge to be
shaved flat 3/4" from each front corner of opening.
Tile Countertops – may need trim cut back 3/4" from each front corner
of opening and /or rounded edge flattened.
For existing cutout width greater than 30-1/16" reduce the 3/4" overlap
dimension; for cutout width of 29", replace actual side trim panels with
smaller side trim panels, available with optional Side Trim Kit (refer to
detailed kit installation instructions).
OPTIONAL ACCESSORIES
Rear Filler Kit: White – (PN # 901193-9011), Black – (PN # 901193-9010).
Side Panel Kit: White – (PN # 903074-9011), Black – (PN # 903074-9010).
Backguard Kit: Stainless Steel – (PN # 903046-901S),
White – (PN # 903046-9011), Black – (PN # 903046-9010).
Side Trim Kit: White – (PN # 903076-9011), Black – (PN # 903076-9010).
Bottom Trim Kit: White – (PN # 903068-9011), Black – (PN # 903068-9010).
Specifications subject to change. Accessories information available on the web at frigidaire.com
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
30" Electric Drop-In Range
Frig Baseline
Front
30"
31
1
/2"
26
1
/2"
25
1
/2"
Overall
depth
including
oven door
in 90° open
position –
47
9
/16"
Power supply
connection
location (left
bottom rear)
28
5
/16"
Side
21
3
/4"
Front Face of Cabinet
22
7
/8"
min.
23
1
/4"
max.
1
1
/8"
21
3
/4"
min.
22
1
/8"
max.
**
Countertop
1
1
/2"
max.
Shave raised
edge to clear
space for
31
1
/2" wide
cooktop rim
27
1
/2"
min. if
additional front
cabinet filler panel
is required (refer to product
installation guide on web
for filler panel details)
13"
max.
30"
min.
18"
min.
24"
min.
1
/2"
min.
WALL
31
1
/2"
(critical)
Hatched area
should be flat
and leveled
30
±
1
/16"
*
1
/2"
min.
Locate grounded
junction box in adjoining
cabinet 2"- 4" from floor
Locate cabinet
doors 1" min.
from cutout
opening
1
/4"
min.
24" min. clearance
with protected cabinet bottom
30" min. for unprotected
30
±
1
/16"
*
29"
*Cabinet and countertop cutout width should match
**24" with optional backguard installed
21
3
/4"
min.
22
1
/8"
max.
**
Approx.
1
7
/8"
Front cabinet filler
(if required)
FFED3026T S /W / B
DROP-IN RANGE
30" ELECTRIC