Installation instructions

4
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For gas venturi models with electric ignition)
C. Level and Position Range - Level range by adjusting the
(4) leveling legs with a wrench. Note: A minimum clearance
of 1/8" is required between the bottom of the range and the
leveling leg to allow room for the bracket. Use a spirit level
to check your adjustments. Slide range back into position.
Visually check that rear leveling leg is inserted into and
fully secured by the Anti-Tip Bracket by removing lower
panel or storage drawer. For models with a warmer drawer
or broiler compartment, grasp the top rear edge of the
range and carefully attempt to tilt it forward.
2. Provide an adequate gas supply.
This appliance is factory pre-set to operate on 4" natural gas
manifold pressure. A gas pressure regulator is connected to
the manifold and MUST be connected in series with the gas
supply line.
Care must be taken during installation of the appliance not to
obstruct the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water column
pressure. The inlet pressure to the regulator must be at least
1 inch greater than regulator manifold pressure. Examples: If
regulator is set for natural gas 4 inch manifold pressure, inlet
pressure must be at least 5 inches.
Leak testing of the appliance shall be conducted according to
the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
3. Seal wall openings.
Seal any openings in the wall behind the range and in the floor
under the range after gas supply line is installed.
Fig. 4a
Fig. 4b
Fig. 4c
Wall
Edge
23"
15"
2"
7"
11-1/2"
10-1/2"
Recommended area for
120V outlet on rear of
wall and area for thru
the wall connection of
pipe stub and shut-off
valve is shaded area.
Recommended area for thru
the floor connection of
pipe stub and shut-off valve.
Centerline
of range
Centerline
of range
C
L
4. Connect the range to the gas supply.
NOTE: To prevent leaks use pipe joint sealant on all male
(outside) pipe threads.
*Please note:
Models without
self-cleaning
feature may
have an
additional 4 to
7 inches
clearance from
the floor.
*