Installation Guide
7
GAS WALL OVEN INSTALLATION INSTRUCTIONS
Figure11
Checkforleaks. After connecting gas, check
system for leaks with a manometer. If a manometer
is not available shut all pilots o (if present), turn
on the gas supply to the unit and use a liquid leak
detector at all joints and connections.
Tightenallconnections if necessary to prevent
gas leakage in the wall oven or supply line.
IMPORTANT: A pipe joint sealant resistant to the
action of LP Gas must be used on all pipe connec-
tions.
Do not use a ame to check for leaks
from gas connections. Checking for leaks with a
ame may result in a re or explosion.
Remove storage drawer by pulling drawer out to
stops. Lift drawer front to clear stops and pull out.
Locate pressure regulator on lower back wall and
convert as shown in Figure 11.
1. Remove the cap from the pressure regulator.
2. Remove the plunger.
3. Turn the plunger upside down with the enlarged
end TOWARDS regulator.
4. Replace the plunger inside the regulator. The
letters LP or 10" W.C. should be visible on the
exposed end of the plunger.
5. Replace the cap on the pressure regulator.
NOTE: The type of gas pressure the regulator is set
for is indicated on the top of the plunger.
Disconnecttheovenanditsindividualshuto
valve from the gas supply piping system during
any pressure test greater than ½ psig.
Isolatethewallovenfromthegassupplypiping
system by closing its individual manual shuto
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less
than ½ psig.
8.LP/PropaneGasConversion
A.PressureRegulatorConversion
Note: Do not remove the Pressure Regulator.
These models have an electric broiler element. No
adjustments are required to this element during fuel
type conversion.
ConvertthePressureRegulatorforusewithLP
Gas (see Figure 11).
Figure10c
Figure10b
Valveclosed
Valveopen
Pressure
Regulator
Spring
DO NOT
REMOVE
Place hollow
end towards
regulator for
NATURAL GAS.
Place solid
end towards
regulator for LP/
PROPANE GAS..
Plastic
Conversion
Plug
Gasket
Cap
To remove from or lock in
cap: Turn conversion
plug 1/4 turn.