Welcome to the world of simple handling and no worries Thank you for choosing Frigidaire. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. Please read all of the instructions before using the air conditioner and keep this manual for future reference. We know you will enjoy your new air conditioner and thank you for choosing our product. We hope you will consider us for future purchases.
Contents 01. Welcome, 02. Environmental advice. 03. Contents... 04. Safety precautions 05. Installation: 5.1 Choosing the installation site 5.2 Parts list. 3 Indoor unit installation 4 Outdoor unit installation. 5 Refrigerant piping connection & Electrical work... Purging the system Electrical safety... Gas leak check... 5.10 Initial operation test.
= Safety precautions | This appliance must be installed by o qualified licensed VAC _ technician in accordance with oll applicable codes. All electrical connections should be performed by a licensed electrician. Manufacturer's warranty will be voided with failure to comply. Incorrect Handling sound result in Serious Injury or Death! 1. Do not attempt to install the split ir 11, Do net climb on or place objects conditioner by yourself. on the outdoor unit. 2. This cir conditioner contains no 12.
Choosing the installation site Installation Warnings 1. Carefully read the installation manual before beginning 2. Follow each step as shown. 3. Observe all local, state and national electric codes. This appliance must be installed by a qualified licensed VAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. Failure fo comply will result in a void of the manufacturer's warranty. 4, Pay attention to all safety notices.
indoor Unit install unit where air flow will not be obstructed. . The installation location must support the weight of the indoor unit, . The site must be easily accessible for maintenance and replacement of the air filler. . The installation location must allow for the necessary space around the indoor unit, as shown in the figure 11 . There should be at least 3 feet {1 meter) between the unit and radio or television devices. It is ideal that the unit be installed at the center of the wall, .
Part list NUMBER PART NAME ary. ary. {ult Split) 1 Wall Mounting Bracket 1 2 Drain Joint (Heat Pump only) 1 1 a Self-tapping screws capacity < 18000 Bi's 5 (For Wail mounting Bracket) capacity 21400 Btu's 7 © 4 Remote Control! 1 Liquid side 1/4 5 Connecting pipe 3/8" (capacity 5 12000 Btu's) 1 .
More than 8" Indoor unit More than 8” More than More than ~ Cc Outdoor unit More than Breve i g Attention! 1. This illustration is for explanation purposes only. 2. Copper tubes must be insulated independently.
indoor unit installation Wall mounting brackets and dimensions & ar more from the acting Wall mooning bracket Indoor unit out & or mare from the — i Refrigerant pipe hole Trig © 2 Refrigerant pipe BG 2.56" Ar £12000 Bs &orm sh opi Incisor unit ling 1 or mare & or mor from the wail From fhe wai ad =18000 Btu's {A3697 B11.737 door unit aul 4 or moe Fran tho wall ar pipe it 0 2.
6 ot more from he coll mare he wall wall mounting bracket lade eit bowleg, 6 oc moral iron the wall Ps | Refrigerator pipe Refrigerant pi es a hole rights hole fight © 2.56" 228000 Bess (A535 B12.83Y Installing the Wall Mounting Bracket 1. Install the wall mounting bracket the wall with eight A type screws. horizontally over the structural 4. At all dimes securing to the wall parts on the wall using the spaces studs is recommended. indicated on the bracket, as shown in figure 1.3. .
Connective pipe and drainage installation Connective pipe 1. For the handler and right hand piping, remove the pipe cover from the side panel. The pipe cover can be kept as it may be used when relocating the air conditioner to any other place 2. For the lighthearted and neanderthal piping, install the piping as shown in figure 1.4. Bend the connective pipe to be laid at a height of or less from the wall. Fix the end of the connective pipe. Drainage 1. Run the drain hose sloping downward.
| 3. Piping can easily be made by filing the indoor unit with « cushioning material between the indoor unit and the wall. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side lo side, up and down to check if it is hooked securely. / Cushioning material | Piping and wrapping . 1. Bundle the tubing, connecting cable, and drain hose with tape securely and evenly as shown in the side ward figure. 2.
Outdoor unit installation 1. Install the outdoor part of the unit on a flat surface to avoid excess noise and vibration. A condenser pad is recommended 2. Direct the air vent forward an ares without obstacles. 3. Install the unit of the site where it is exposed to as file wind as possible, especially in areas where it is frequently windy. 4, It the installation site is exposed fo heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates. 5.
| Condensate drainage of outdoor unit {ruling only excluded} The condensate and defrosting water produced during heating in the outdoor unit can be properly discharged by drainage pipe. Installation method: Insert the drain connection into one of the holes of the chassis and then connect drainage pipe with drain nozzle. insert drainage plugs {with different appearance} into the other holes.
Refrigerant piping connection Unit comes with 25' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the Haring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A} Use the piping kit accessory or pipes purchased locally. BJ Measure the distance between the indoor and the outdoor unit.
| 4. Flaring work. Firmly hold copper pipe in a die in the dimension shown in the label below. OUTER A finch DIAMETER nck) 0.051 | 0.028 8 0.063 | 0.039 192 0071 | 0.039 5/8 0.005 | 0.087 handle Connection Adjustment . Align the pipes to he connected. Screw the flare nut with your ¢ ’ fingers, and then tighten it with o Indoor unit ERA spanner and torque wrench, as gibing nut shown in figure 1.6. Figure 1.6 Caution: Excessive twisting may break the nut, depending on the installation conditions.
Electrical work Electric safely regulations for the initial installation 1. It there is serious safety problem 4. Ensure the air conditioner is about the power supply, the grounded well. technicians should refuse to install 5. All wiring must comply with local + the air conditioner and explain and national electrical codes and fo the client until the problem is be installed by qualified and skilled solved. electricians. | 2. Power voltage should meet the 6.
Conn ext the cable to the indoor unit . The inside and outside connecting Electrical box cable can be connected without cover removing the front grille / . Connecting cable between indoor unit and outdoor unit shall be approved polypropylene sheathed flexible type cord. . Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. . Ensure the wire color of the outdoor terminal and indoor terminal correspond respectively. .
Connect the cable to the outdoor unit 1 . Remove the electrical control board . Connect the connective cables to . Secure the cable onto the control . To prevent the ingress of water, Cable . Insulate unused cords (conductors) —— cover from the outdoor unit by loosening the screw. the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective cable to power supply shall be approved polypropylene sheathed exile cord.
Caution . After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the ir conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. . The screws which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations fo which the unit is subjected during the course of transportation.
Purging the system with o vacuum pump 1. Check that each tube (both liquid and gas side tubes] between the indoor and outdoor units have hen properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed of this slag. 2. When relocating the unit to another place, perform evacuation using vacuum pump. 3.
3 Paige length and refrigerant amount for multi split type air conditioner {see towel 2.3] Tobit 2.3 Competencies | Max livelong pie sro lane fx, Tor gh 4 A page 2505 FET so Use sacs pie, Use vac sep. Lx 14 Ls indoor unit _ Caution in handling the packed valve integrated in the outlets of outdoor unit. 1. Operation of opening packed valve: Open the valve stem unfit it hits against the stopper. Do nat Iry to open it further 2.
When using the vacuum pump For method of using a manifold valve, refer fo its operation manual. 1. Completely tighten the flare nuts at connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect vacuum hose to valve core fool. Open the charade valve. Note: The charade valve is inside the charging port. 2. Connect the other charge hose of manifold valve fo the vacuum pump. 3. Fully open the Low Side handle of the manifold valve. 4. Operate the vacuum pump fo evacuate.
Electrical safety | Perform the electric safety check after completing installation: . Insulated resistance: The insulated resistance must ke more than 2M . Grounding work: Alter finishing grounding work, measure the grounding resistance by visual detection and grounding resistance Lester. Make sure the grounding resistance is less than 4. .
initial operation test Perform fest operation after completing gas leak check af the flare nut connections and electrical safety check 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. 2. Use the MODE button to select COOL, HEAT [Only for models with heating function}, AUTO and FAN to check if all the functions work well 3.