Welcome to the world of simple handling and no worries Thank you for choosing Frigidaire. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. Please read all of the instructions before using the air conditioner and keep this manual for future reference. We know you will enjoy your new air conditioner and thank you for choosing our product. We hope you will consider us for future purchases.
Contents 01. Welcome, 02. Environmental advice. 03. Contents... 04. Safety precautions 05. Operation: 5.1 Preparing the device for operation 5.2 Product description 5.3 Remote control... « Remote control operation Remote control specifications Remote control battery ~ When should the batteries be replaced «To replace batteries Remote control instructions 5.4 Remote control description. 5.5 Special functions. 5.6 How the air conditioner works.
Safety precautions This appliance must be installed by o qualified licensed VAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. Manufacturer's warranty will be voided with failure to comply. Incorrect Handling sound result in Serious Injury or Death! 1. Do not attempt to install the split air conditioner by yourself. 2. This cir conditioner contains no user-serviceable parts.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due fo ignoring of instructions may course harm or damage. The seriousness is classified by the following indications. 1. Connect with the power properly {confirm voltage upon installation} Otherwise, it may cause electric shack or fire due fo excess heat generation. 2. Always ensure effective grounding. Mo grounding may cause electric shack. 3.
20. Do not open the unit during aeration. lt may cause electric shock or injury. . Do not drink water drained from air conditioner. It may contain contaminates that could make you sick. . Do not disassemble or modify unit, It may cause failure of appliance, electric shock and void the warranty. . When the air filter is io be removed, do not touch the metal parts of the unit. lt may course an injury. . When the unit is to be cleaned, power off, and turn off the circuit breaker.
Preparing the device for operation 1. Contact a licensed specialist fo install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner, ensure that the air filter is installed correctly 4, If the unit has been out of use for a long priced of time, it is recommended that the air filter be cleaned before use. During continuous use, clean the air filter every two weeks. 5.
Product description EB Front panel FI Air filer Eh {beneath front panel} Horizontal airflow grille ol Vertical airflow grille 4° £1 Air outlet [i Temperature sensor {inside the indoor unit) a Display Infrared signal receiver B Refrigerant gas connection Remote control EL Connecting cable ill Detection valve ond packed valve shield IB Drain hose and refrigerant connecting pipe Ar inlet Ar inlet i Air outlet Outdoor unit Attention!! All the pictures in this manual are for explanation purpose only.
Display panel {indoor unit} EE! HEAT indicator: This indicator illuminates when the air conditioner is in heat operation. [EZ cool indicator: This indicator illuminates when the air conditioner is in cool operation. FE3 DIGITAL SCREEN: Show the present adjustments to temperature when wir conditioner is operating 2 OPERATION indicator: This indicator illuminates red after power is on and illuminates green when the unit is in operation.
Remote control Remote control operation 1. Operation mode: Cool, Heat {Only for models with heating function}, DRY, FAN, and AUTO [Automatic]. 2.24 hrs Timer. 3. Internal temperature range selection: E1°F 86°F 4.1CD REMOTE CONTROL SPECIFICATIONS Rated voltage 3V Lowest voltage of CPU emoting signal 24Y Transmission distance Environment 23°F ~ 140°F "With 3 Y reaches 40° Attention! 1.
When should the batteries be replaced 1. There is not o "beep" anymore from the indoor unit when using the control remote or the signal light indicator does not light 2. The indoor unit does not respond 10 the remote control commands to activate the programs. To replace batteries 1. Slide out the battery compartment cover { located of the back of the remote control). 2. Install two AAA batteries in the compartment {indicated in the drawing located inside the compartment]. 3.
Remote control description Connective pipe and drainage installation B ON/OFF; Press this button to start Tooling and heating model the unit operation. Push the button 1 again fo stop the unit operation.
EJ CLOCK: Press this bunion, the clock can be set up, icon (3) blinks. Within 5 seconds, the value con be adjusted by pressing "+ or button, if continuously press this bunion for 2 seconds above, in every 1/2 second, one minute will be increased, if you are still pressing the button after ten minutes increased, ten minutes will be increased Avery 1/2 second. During blinking, repress the Clock button and icon (3) will be constantly displayed ond it denotes the setting has succeeded.
1a How the air conditioner works Automatic operation When the Air Conditioner is ready for use, switch on the power and the OPERATION indicator lamp on the display panel of the indoor unit sorts illuminating. 1. Use the MODE button lo select AUTO. 2. Use the "MODE" button to select Auto. The unit will automatically select Cool, Fan and Heat operation depending on the difference ambient temperature and system difference temperature. When in Cool Operation the panel will display 77 °F.
DRY (HUMIDIFICATION) operation The dry mode will automatically select the drying operation based on the difference between the set temperature and the actual room temperature. The temperature is regulated while dehumidifying by repeatedly turning on and off of the cooling operation or fan only. The fan speed is mainly LOW. 1. Press the MODE button fo select DRY. 2.
SLEEP mode{Only for >12000 Btu's} Press the sleep button to activate the sleep mode. To deactivate, press the button again. In cooling made: © The fan speed will be automatically controlled. © The air conditioner will automatically § & increase 2 °F per hour in a 2 hour 5 beer period. The set temperature will be Fe] steady for the next 5 hours, then this SLEEP FUNCTION (Cooling mode) mode will be terminated.
To set the stopping dime 1. Press the "TIMER OFF" button to activate the auto start timer function. 2. The method of setting is the same as above of TIMER ON". Examples: Jos. 12h 1h 20h 23h Highway On) timer OF) chimer OF] {Timer On} Chi co Ord {Timor OF Optimal operation To achieve optimal performance, please note the following: 1. Adjust the air flow direction correctly so that it is not directed on people. 2. Adjust the temperature to achieve the highest comfort level.
How to use the indoor unit Adjusting air flow direction Adjust the air flow direction properly, otherwise it might cause discomfort or uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually.
The 31 button will be disabled when the air conditioner is not in operation {including when the TIMER ON is serf. Do not operate the air conditioner for long periods with the ir low direction sef downward in cooling or dry mode. Otherwise, condensation may occur on the surface of the horizontal louver and drop on to the floor or on furnishings. Do not move the horizontal louver manually. Always use the 38 bunion. if you move this louver manually, it may malfunction during operation.
Manual operation {without remote control) Manual operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted. 1. Open and lift the front panel up to an angle until it remains fixed with a clicking sound. 2. One press of the manual control button will lead fo the forced AUTO operation. 3. Close the panel firmly to its original position. Manual control button Auto/OFF © Attention! order as: AUTO and OFF. the remote controller.
Maintenance Cleaning the indoor unit and remote controller 1. li is necessary fo stop the air conditioner and disconnect the power supply before cleaning. 2. Use a dry cloth to wipe the indoor unit and remote controller. 3. A cloth dampened with cold water may be used on the indoor unit if it is very dirty. 4, The front panel of the indoor unit can be removed and cleaned with water. Then wipe it with a dry cloth. 5. Do not use a chemically treated cloth or duster io clean the unit. &.
Maintenance If you plan to idle the unit for a long ime, perform the following 1. Operate in fan mode for about half a day fo dry the inside of the unit. 2. Stop the air conditioner and disconnect power. Remove the batteries from the remote controller. 3. The outdoor unit requires periodic maintenance and cleaning. Do not attempt to do this yourself. Contact your dealer or service. If you plan fo idle the unit for a long dime, perform the following: 1. Check that the wiring is not broken or disconnected. 2.
Operation dips The following events may occur during normal operation. Protection of the air conditioner. Compressor protection This unit comes with a dime delay function to help protect the compressor, please allow 3 minutes for the compressor fo restart upon turning on the unit. Angelical air [Only for models with heating function, The unit is designed not fo blow cold oir in HEAT mode when the indoor heat exchange is in ane of the following three situations and the set temperature has not been reached.
Dust is blown out from the indoor unit, This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit. A peculiar smell comes out from the indoor unit. This is because the indoor unit gives off smells permeated from building material, furniture or smoke. The oir conditioner turns to FAN only mode farm COOL or HEAT {Only for models with heating function) mode.
Solution for problems if your air conditioner malfunctions, check the following information to find solutions or probable causes of the failure. Do not fry to repair the unit by yourself, if these solutions do not solve the failures, call your local service repair team. Poor Equipment performance 1. The air leaflet or inlet of outdoor unit is obstructed. 2. The air outlet or inlet of indoor unit is obstructed. 3. The outdoor temperature is high due to direct sunlight or anther hast source. 4.
Major Appliance 5 Year Parts Only Limited Warranty Your appliance is covered by a five year parts only limited warranty. For five years from your original date of purchase, Electrolyte will pay for the cost of replacement parts used in the repair of the appliance if the original parts prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions. Exclusions This limited warranty does not cover the following: 1.
Major Appliance 5 Year Parts Only Limited Warranty DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED PARTS ONLY WARRANTY SHALL BE THE COST OF REPLACEMENT PARTS AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR.