ICE MAKER INFORMATION
Turn the IM ON and OFF: Press and hold the POWER button for ½ second to turn the IM ON and OFF. When the IM is ON, the Power button will be illuminated solid green
Test Cycling: Press and release the TEST/SERVICEbutton to start the self-diagnostic function. The tray will perform two rotations. The ice level arm must be held so that it does not drop during the rst rotation (simulating full ice bin). Once the
tray returns to the Home position, the arm can be released. Allow the arm to drop normally during the the second rotation (simulating empty ice bin). Once the tray returns Home after the second rotation, the POWER button will change back to
solid green if no errors were detected during the test. This means the IM operates properly. If errors are detected at any time during the test, the test will stop immediately and the POWER button will blink rapidly continuously. In this case, there
is some internal failure of the IM. NOTE: If the arm is not held during the rst rotation, the IM will indicate a failure falsely. To run the test again to verify, the IM must be turned OFF and back ON.
Manual Water Fill: Press and hold the TEST/SERVICE button for 3+ seconds.
Adjust Water Fill Size: Press and hold the POWER and TEST/SERVICE buttons together for 3 seconds. The POWER button will blink to show the current setting.
1 blink = small, 2 blinks = med, 3 blinks = large, 4 blinks = extra large. Press the TEST/SERVICE button to advance to the next level. When at extra large, the next press goes back to small. The factory default is small.
SERVICE DATA SHEET
A17276301
STANDARD - AUTOMATIC DEFROST
TOP MOUNT FREEZER - R600a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel only.
Untrained persons should not attempt to make repairs due to the possibility of electrical
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to
their original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch ame. DO NOT
allow torch to touch insulation; it will char at 200°F and ash ignite (burn) at
500°F. Excessive heat will distort the plastic liner.
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
SERVICE MODE
SERVICE MODE will step through available tests to diagnose individual electrical cir-
cuits. Fresh Food compartment light will be OFF while in SERVICE MODE.
enter/exit
--> Press the door switch 3 times and hold the 4th press until
the FF light turns on. When switch is released the light should
turn o. The door switch must be pressed 4 times in 2 seconds.
initiate rst/
next test
--> Press the door switch 2 times.
1 Compressor Press the FF door switch twice to start the rst test. In each
test, the component listed will be powered on. The compo-
nent will stay powered until the next test is activated, or until
5 minutes of inactivity expire. Listen for operating sounds;
feel for heat or air ow, as appropriate, to determine the
result of each test. Press the FF door switch twice again to
advance between tests.
2 Heater
3 FF Light
4 Evaporator Fan
PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A With Run/
Start Capacitor
70°F (21.1°C)
Ambient
90°F (32°C)
Ambient
Operating Time 26 to 29% 45 to 47%
Freezer Temperature to -2.2°F
(-15° to -19°C)
to -2.2°F
(-15° to -19°C)
Refrigerator Temperature 35° to 40°F
(2° to 4°C)
35° to 40°F
(2° to 4°C)
Low Side Pressure
(cut-in)
-3.24 to 0.80 psig
( 79 to 107 kPa)
-3.24 to -0.66 psig
(79 to 97 kPa)
Low Side Pressure
(cut-out)
-6.70 to -6.19 psig
(55 to 59 kPa)
-6.59 to -6.22 psig
(56 to 58 kPa)
High Side Pressure
(last 1/3 cycle)
38 to 39 psig
(364 to 372 kPa)
57 to 58 psig
(498 to 503 kPa)
Wattage (last 1/3 cycle) 68 W 68 W
Amps (running) 0.6 to 0.8 A 0.6 to 0.8 A
Base Voltage 115 V 115 V
Refrigerant Charge 1.58 oz. (45 g)
DEFROST SPECIFICATIONS
Cabinet Size: 14'
Thermal Fuse Heater
Defrost
Thermistor
Cut-out Watts Ohms Termination
161.6°F
(72°C)
166 79.7
48°F
(8.89°C)
EVAPORATOR FAN MOTOR
Watts RPM Amps
3.1 (max) 2700 CW 0.258 Running
ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max) 60 Hertz
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Light Blue Neutral
2 Yellow Water Valve
3 Black Line
Normal Cooling
Mode
Enters Service
Mode
Test 1:
Compressor ON
Test 4: Evaporator
Fan ON
Test 2: Power ON
to Defrost Heater
To Exit Service Mode from
any Test Press Door Switch
3 Times and Hold 4th Press
Service Mode
Test 3: Fresh
Food Light ON
Press Door Switch
2 Times
Press Door Switch 3
Times and Hold 4th Press Until
the FF Light Turns On
Manual Defrost
Press Door Switch 5 Times to
Enter Manual Defrost. POR
or Enter Service Mode to Exit
Manual Defrost.
Press Door Switch
2 Times
Press Door Switch
2 Times
Press Door Switch
2 Times
Press Door Switch
2 Times
108 mm
44.5 mm
P/N A01437001
MANUAL DEFROST
Unit will complete normal defrost cycle.
enter --> Press the FF door switch 5 times in 2 secs.
exit --> Cycle power to the unit or enter and exit
SERVICE MODE. (See SERVICE MODE)
Defrost is terminated when defrost thermistor located on the evaporator coil reaches
48°F (8.89°C).
IMPORTANT
START-UP NOTE: Upon 1st start-up or power cycle, the compressor will
come on after 15 seconds and run for 4 minutes. If the door switch is not
cycled during this time, the compressor may cut o after 4 minutes and not
turn back on for another 3 minutes. It may take up to 10 minutes for the
compressor to turn on and run in normal mode.