Installation guide

INSTALLATION
REQUIREMENTS
&
NOTE
Because
of
potentially
inconsistent
voltage
capabilities,
the
use
of
this
dryer
with
power
created
by
gas
powered
generators,
solar
powered
generators,
wind
powered
generators
or
any
other
generator
other than
the
local
utility
company
is
not
recommended.
Electrical
requirements
for
Laundry
Center
with
electric
dryer
CIRCUIT
-
Individual
30
amp.
branch
circuit
fused
with
30
amp.
time
delay
fuses
or
circuit
breakers.
POWER
SUPPLY
-
3-wire
or
4-wire,
240
volt,
single
phase,
60
Hz,
Alternating
Current.
=a
IMPORTANT:
This
laundry
center
is
internally
grounded
to
neutral
unless
it
was
manufactured
for
sale
in
Canada.
Only
a
4-conductor
cord
shall
be
used
when
the
appliance
is
installed
in
a
location
where
grounding
through
the
neutral
conductor
is
prohibited.
Grounding
through
the
neutral
link
is
prohibited
for:
(1)
new
branch
circuit
installations,
(2)
mobile
homes,
(3)
recreational
vehicles,
and
(4)
areas
where
local
codes
do
not
permit
grounding
through
the
neutral.
OUTLET
RECEPTACLE
-
NEMA
10-30R
or
NEMA
14-30R
receptacle
to
be
located
so
the
power
supply
cord
is
accessible
when
the
dryer
is
in
the
installed
position.
GROUNDING
CONNECTION
-
See
“Grounding
requirements”
in
Electrical
Installation
section.
3-WIRE
POWER
SUPPLY
CORD
KIT
(not
supplied)
3-wire
receptacle
|
(NEMA
type
10-30R)
The
dryer
MUST
employ
a
3-conductor
power
supply
cord
NEMA
10-30
type
SRDT
rated
at
240
volt
AC
minimum,
30
amp,
with
3
open
end
spade
lug
connectors
with
upturned
ends
or
closed
loop
connectors
and
marked
for
use
with
clothes
dryers.
For
3-wire
cord
connection
instructions
see
ELECTRICAL
CONNECTIONS
FOR
A
3-WIRE
SYSTEM.
4-WIRE
POWER
SUPPLY
CORD
KIT
(not
supplied)
4-wire
receptacle
(NEMA
type
14-30R)
The
dryer
MUST
employ
a
4-conductor
power
supply
cord
NEMA
14-30
type
SRDT
or
ST
(as
required)
rated
at
240
volt
AC
minimum,
30
amp,
with
4
open
end
spade
lug
connectors
with
upturned
ends
or
closed
loop
connectors
and
marked
for
use
with
clothes
dryers.
For
4-wire
cord
connection
instructions
see
ELECTRICAL
CONNECTIONS
FOR
A
4-WIRE
SYSTEM.
&
NOTE
Laundry
centers
manufactured
for
sale
in
Canada
have
factory-installed,
4-wire
power
supply
cord
(NEMA
14-
30R).