Installation guide

Gas connection
1 Remove the shipping cap from gas pipe at the rear 3 Open the shutoff valve in the gas supply line to
of the dryer, allow gas to flow through the pipe. Wait a few
minutes for gas to move through the gas line.
DO NOT connect the dryer to LP, gas service without
converting the gas valve. An L.P.conversion kit must
be installed by a qualified gas technician.
2 Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or
approved pipe from gas supply line to the 3/8 inch
(0.96 cm) pipe located on the back of the dryer.
Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm)
reducer for the connection. Apply an approved
thread sealer that is resistant to the corrosive
action of liquefied gases on all pipe connections.
Manua GAS FLOW "_
Shutoff Flare _ Flare |
Valve Union Union |
/
,o_/:_ed:l_Fi_'_i l\':_:::l_:_\\_/_'i l_/
: ,1_I t ' t t [
\. Nipple Flexible Inlet Pipe on |
Open Connector Back of Dryer |
AHconnectionsmust be wrench-tightened J
Open position
4 Check for gas system leaks with a manometer. If a
manometer is not available, test all connections by
brushing on a soapy water solution.
EXPLOSION HAZARD
.EwRtestforgasleakswithanopen,ame.
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in
the same room as the dryer and should be in a location
that allows ease of opening and closing. Do not block
access to the gas shutoff valve.