Installation guide

16
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal
block access cover on the back of the dryer.
3. Install a UL-approved strain relief according
to the power cord/strain relief manufac-
turer’s instructions in the power cord entry
hole below the access panel. At this time,
the strain relief should be loosely in place.
4. Thread an UNPLUGGED, UL-approved, 30
amp. power cord, NEMA 14-30 type DRT
or SRDT, through the strain relief.
Move internal ground (WHITE)
wire to neutral (SILVER)
terminal for 4-wire system.
Neutral
terminal
GREEN
ground screw
BLACK or
RED power wire
BLACK
or RED
power wire
GREEN
ground wire
WHITE
neutral wire
Neutral
(WHITE
wire)
30 AMP
NEMA 14-30
Ground
(GREEN
wire)
Electrical connection
(non-Canada) - 4 wire cord
INSTALLATION INSTRUCTIONS
5. Disconnect the internal (WHITE) dryer
harness ground wire from the (GREEN)
ground screw next to the terminal block.
6. Attach the ground (GREEN) power cord wire
to the cabinet with the ground (GREEN)
screw. Tighten the screw securely.
7. Move the internal dryer harness ground
(WHITE) wire to the terminal block and
attach it along with the neutral (WHITE)
power cord wire conductor to the center,
SILVER colored terminal on the terminal
block. Tighten the screw securely.
8. Attach the RED and BLACK power cord
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten
both screws securely.
4-wire receptacle
(NEMA type 14-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before
servicing could result in personal injury or
even death.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT make a sharp bend or crimp wiring/
conductor at connections.
9. Follow manufacturer’s guidelines for rmly
securing the strain relief and power cord.
10. Reinstall the terminal block