Installation Instructions

15
1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block
access cover on the back of the dryer.
3 Install a UL-approved strain relief according to the
power cord/strain relief manufacturer’s instructions
in the power cord entry hole below the access
panel. At this time, the strain relief should be
loosely in place.
4 Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 10-30 type SRDT, through the
strain relief.
5 Attach the power cord neutral (center wire)
conductor to the SILVER colored center terminal on
the terminal block. Tighten the screw securely.
6
Attach the remaining two power cord outer
conductors to the outer, BRASS colored terminals on
the terminal block. Tighten both screws securely.
7 Follow manufacturer’s guidelines for rmly securing
the strain relief and power cord.
8 Reinstall the terminal block cover.
Neutral
terminal
DO NOT remove
internal ground in a
3-wire system!
Electrical connection (non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
Neutral
Neutral
(center wire)
(center wire)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor
at connections.
IMPORTANT
If moving dryer from a 4-wire system and installing it
in a 3-wire system, move the internal ground from the
center terminal back to the GREEN screw next to the
terminal block.
INSTALLATION INSTRUCTIONS