All about the Use & Care of your Portable Air Conditioner TA B L E O F C O N T E N T S Important Safety Instructions ............................... 2-3 Air Conditioner Features ...................................... 8 Product Registration ............................................. 4 Operating Instructions ......................................... 9-11 Normal Sounds .................................................... 4 Care and Cleaning ...............................................
Important Safety Instructions NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the portable air conditioner only as instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
Important Safety Instructions SAFETY PRECAUTIONS CAUTION! Avoid Injury or damage to the unit or other property Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively. Do not climb on or place objects on the unit. Do not hang objects off the unit. Do not place containers with liquids on the unit.
Product Registration & Normal Sounds Product Registration Record Your Model and Serial Numbers Record in the space provided below the model and serial numbers. On all models, the serial plate is located on the side of the cabinet. Model No. Serial No. Register Your Product The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed and returned to the Frigidaire Company. Normal Sounds 6RXQG RI 5XVKLQJ $LU $W WKH IURQW RI WKH XQLW \RX PD\ KHDU WKH VRXQG RI UXVKLQJ DLU EHLQJ PRYHG
Unit Description & Accessories Included Unit Description CONTROL PANEL AIR INTAKE ROOM AIR DISCHARGE DEHUMIDIFYING DRAIN OUTLET CARRYING HANDLE (BOTH SIDES) EXHAUST AIR OUTLET REMOTE SIGNAL RECEIVER REMOTE CONTROL on·o ff mod e speefan d temp sleep time on r time off r CASTOR Fig.
Installation Instructions Installation Instructions EXHAUSTING HOT AIR In the COOLING Mode the appliance must be placed close to a window or opening so that the warm exhaust air can be ducted outside. First position unit on a flat floor and make sure there’s a minimum of 12" clearance around the unit, and is within the vicinity of a single circuit outlet power source. 1. Extend either side of the hose (Fig. 3) and screw the hose to adaptor A (Fig. 4) . 2.
Installation Instructions Installation Instructions (continued) Installation in a double-hung sash window 1. Cut the foam seals(adhesive type) to the proper lengths and attach them to the window and stool. (Fig. 10) 2. Open the window sash and place the window slider kit on the window stool (Fig. 11). Attach the window slider kit to the window stool. Adjust the length of the window slider kit according to the width of window. Screw down the two screws on the window slider kit. See Fig.11.
Air Conditioner Features Air Conditioner Features CONTROL PANEL DISPLAYS TEMPERATURE . CHECK FILTER SETS MODE RESET BUTTON TURNS UNIT ON OR OFF ADJUSTS TEMPERATURE Fig. 21 REMOTE CONTROL ON/OFF BUTTON on·off MODE SELECTOR mode FAN SPEED SELECTOR fan speed SLEEP BUTTON sleep TEMPERATURE BUTTON timer on temp timer off TIMER BUTTONS Fig. 22 Battery Size: AAA Warning: 1. Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickelcadmium) batteries. 2.
Operating Instructions Operating Instructions NOTE Some of the following instruction can only be activated by using remote control. COOLING MODE: In this mode the exhaust adaptor hose MUST be used. 1. Press the MODE button until the "Cool" indicator lights. 2. Press the " " Temp buttons for desired setting. 3. Press the FAN button on the remote control for desired fan speed.
Operating Instructions Operating Instructions (continued) CHECK FILTER FEATURE: SELECTING FAN SPEED: AUTO LOW HIGH MED This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) which above the "Filter" button will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Filter" button and the light will go off. You can select the desired fan speed, by pressing the FAN SPEED button.
Operating Instructions, CARE & CLEANING Operating Instructions (continued) ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.
Before You Call Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE SOLUTION Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet. Plug Current Device Tripped. Press the RESET button. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Control is OFF.
Major Appliance Limited Warranty Your appliance is covered by a limited one-year warranty and a limited 2-5 year warranty on the sealed system (the compressor, condenser, evaporator and tubing). For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.