Specifications

Specifications
subject to change.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
Front
Side
Top Load Laundry - Washer
Frigidaire Baseline (S Models)
Vented door
6"
min. 2"
min.
Side
60"
sq.
in.
min.
3"
60"
sq.
in.
min.
3"
1"
min. 1"
min.
24"
min.
Front
Recess or Closet Installation
Washer requires 1" minimum installation clearance
on each side of unit and 6" minimum at back. To
achieve 6"
minimum rear clearance when installed
with dryer, dryer MUST use 90° quick-turn vent elbow.
Closet installation requires 2"
minimum clearance
between front of unit and vented door. Door MUST be
vented with 120 sq.
in. minimum louvered opening,
equally divided, located 3" from top and bottom of
door. A louvered door with equivalent air openings for
full-length of door is acceptable. Air openings MUST
remain unobstructed with door installed. For additional
installation details, refer to Product Installation
Guide on web.
27"
59"
29"
38
1
/2"
44
1
/4"
H/C Water
inlets (rear) -
48" hose
length
Drain hose
retention
clamp (rear)
59" Hose
length
beyond
clamp
120V Power
cord (rear) -
70
1
/2"
long
Floor MUST be solid with 1" maximum slope. To minimize vibration
or movement, reinforcement of floor may be necessary. Do NOT
install on carpeted surface.
Leveling legs supplied to level unit properly and reduce excessive
noise and vibration.
H/C water faucets MUST be installed within 42" of washer’s water
inlet and MUST be 3/4" with threading for laundry hose connection
to connect to 48" inlet hoses.
Water pressure MUST be between 30 and 120 psi with NOT more
than 10 psi pressure difference between hot and cold.
Drain standpipe requires diameter of 1-1/4" min. and height of
39" min. / 96" max. above floor, capable of eliminating 17 gallons
per minute. Attached 59" drain hose can reach 74"-high standpipe.
For higher standpipe, optional Drain Hose Extension Kit available.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Drain Hose Extension Kit – (PN # 137098000).
Top Load Washer Specifications
Product Shipping Weight (approx.) – 157 Lbs.
An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (ANSI/NFPA 70) and
local codes & ordinances. (Do not use same circuit as dryer.)
Voltage Rating – 120V / 60 Hz
Amps @ 120 Volts = 8.0 Amps
Equipped with 120V 3-wire power supply cord, approx. 70-1/2" long.
Always consult local and national electric & plumbing codes.
To maximize detergent effectiveness, ambient temperature should
never be below 60° F.
Washer requires 1" minimum installation clearance on each side of
unit and 6" minimum at back. To achieve 6" minimum rear clearance
when installed with dryer, dryer MUST use 90° quick-turn vent elbow.
Closet installation requires 2" minimum clearance between front of
unit and vented door. Door MUST be vented with 120 sq. in. minimum
louvered opening, equally divided, located 3" from top and bottom
of door. A louvered door with equivalent air openings for full-length
of door is acceptable. Air openings MUST remain unobstructed with
door installed. (For additional installation details, refer to Product
Installation Guide on web.)
Do NOT install in area exposed to dripping water or outdoor weather
conditions; or where gasoline or other flammables, including
automobiles, are kept or stored.
FFTW4120S 02/17 © 2017 Electrolux Home Products, Inc.
Top Load Washer
FFTW4120SW 4.1 Cu. Ft. D.O.E.