Installation guide

INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUAUHED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result ]
causing property damage, personal injury or death.
/
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
J WHAT TO DO [F YOU SMELL GAS:
® Do not try to light any appliance.
Do not touch any e[ectrka[ switch; do not use any phone in your building.
immediately ca[[ your gas supplier from a neighbor's phone. Follow the gas suppHer's instructions.
If you cannot reach your gas supplier, calmthe fire department.
-- installation and service must be performed by a qualified installer, service agency or the gas supplier.
Cooktop Dimensions
* 30" min. for unprotected cabinet
24" min. for protected surface
1
30" Min.*
(76.2 cm) Min.*
C
Cooktop Cutout Dimensions
M
Figure 1
. LENGTH .
30" Models 30 (76.2) 21 Y2(54.6) 2!4 (7,0)
36" X 21Yz"Models 36 (91.4) 21 Y2(54.6) 2sA (7,0)
36"X 18" Models 36 (91.4) 18 (45.7) 2!4 (7,0)
MIN. DILENGTH MAX}
26 s/s (67.6) 267/s (68.3)
32 34(83.2) 33 (83.8)
34 ¼ (87) 34 s/s(87.3)
MIN. E. WIDTH MAX.
19 (48.3) 19 s/s (49.2)
19 (48.3) 19 s/s (49.2)
16 s/s(42.2) 16 34(42.5)
COOKTOP* (Min.) , (Min.)
5 (12.7) 2s4(7) 2Y4(5.7)
5 (12.7) 23A(7) 2Y4(5.7)
5 (12.7) 4Y4(10.8) 3 (7.6)
All dimensions are in inches (cm).
Dimension F is for clearance under cooktop for gas connection.
NOTE: Wiring diagrams for these appliances are enclosed in this booklet.
Only some models are available in Canada.
Printed in United States
P/N 318201463 (0508) Rev A
English - pages 1-8
Espanol- pages 9-17
Fran_ais - pages 18-26
Wiring Diagrams - pages 27-28

Summary of content (28 pages)