Product Specifications Sheet

INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 265 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only
electrical supply with ground required on separate circuit fused on both sides
of line.
Connected Load (kW Rating) @ 240 / 208 Volts = 7.4 / 5.6 kW
Amps @ 240 / 208 Volts = 30.8 / 26.9 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Minimum 21" clearance for oven door depth when open.
Suggested distance from floor is 11-1/2". Minimum required distance is 4-1/2".
Minimum 24" deep cutout dimension is critical for proper installation, to ensure
that oven’s faceplate will fit flush against cabinet front.
To adapt oven to fit cutout height greater than 49-1/2", add one 2"-wide wood
shim of appropriate height to each side of opening under oven side rails.
Lifting oven will hide larger cutout opening at top and oven’s 1"-high bottom
trim will hide shims at bottom. (Standard 1"-High Bottom Trim included.)
To adapt oven to fit cutout height greater than 49-7/8", optional 3"-High
Bottom Trim available.
Full oven base of solid plywood or similar material required, capable of
supporting 300 Lbs.
Base must be level and cabinet front must be square.
Double Wall Ovens are NOT approved to be used in stackable or side-by-side
installation.
OPTIONAL ACCESSORIES
3"-High Black Stainless Steel Bottom Trim – (PN #5304520622).
3"-High Stainless Steel Bottom Trim – (PN #5304520626).
10'-Long Armored Power Cable – (PN # 903056-9010).
Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
*Critical dimension – MUST be applied
**For cutout height greater than 49
1
/
2
", add one 2"-wide wood
shim of appropriate height to each side of opening under oven side
rails. Lifting oven will hide larger cutout opening at top and oven’s
1"-high bottom trim will hide shims at bottom.
(Optional 3"-high
bottom trim available for cutout height greater than 49
7
/
8
".)
1
1
/2"
min.
11
1
/2"
suggested
distance
4
1
/2"
min.
required
48
7
/8"
min.
49
7
/8"
max.
2"-wide
wood spacers
(if needed)**
24
7
/8"
1
/4"
min.
25
max.
24"
min.*
(critical
dimension)
2" min.
Electrical
junction
box location
Full base
required
to support
300 lbs.
4" x 4"
opening
to route
armored
cable
27
1
/8"
min.
3" max.
48
5
/8"
24
5
/8"
Spacers
24
3
/4"
Power
supply
location
(left
bottom
rear)
50
7
/16"
(includes
1"
bottom
trim)
27"
Allow at least
21" clearance
for door depth
when open
FGET2766U 03/19
© 2019 Electrolux Home Products, Inc.
FGET2766U F/D
DOUBLE WALL OVEN
27" ELECTRIC