Wiring Diagram

Electronic Surface Element Control System (ESEC) Error Code Descriptions
When a specic error condition occurs in the ESEC system, a code will be displayed in the electronic control panel as shown in the error notication in an induction system section. For each Error Code there is a listing of the likely cause or failure
condition,aswellassuggestedcorrectiveactionstobetaken.Alwaysresetthepowerbydisconnectingorturningothepowersupplyfor30secondstoseeifthefailureconditionwillclear.Iftheerrorcodereturnsperformthestepsoneatatimeintheorderlisted
belowtocorrectthespecicfailurecondition.NOTE: If multiple changing error codes are displayed check for disconnected wires or cables.
Error
Code
Likely Cause or Failure Condition Suggested Corrective Action
E01 Internal error 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E02 Dataasherror 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E03 Congurationerror 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E04 Keyboardtuningcongurationerror 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E05 Keyboard safety error 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E06 HMICOMM_Q_ERROR 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E11
Stuck Key 1. If a key was pressed inadvertently for a long time this error code will be displayed. Make sure there is nothing (water, utensils) in contact with the keyboard. The fault code should go away
once the key is released and the Stop key is pressed. If the error comes back when a key is pressed it means the error condition is still there. If the error does not come back it means the error
condition is gone and the cooktop can be used.
2. If the fault code cannot be cleared, replace hob UI board corresponding to the error.
E12 Keyboardcongurationerror 1. Verify the unit has the proper cooktop user interface board based on the model number and parts catalog.
2. Replace the cooktop user interface board corresponding to the error if the UI is incorrect or the issue persists.
E13 Non-volatile memory alarm 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E15 FMEA error 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E19 Unabletocongurethepowerboard 1. Check the MACS connection (communication harness) between user interface board and induction power boards.
2. If problem persists, check continuity of MACS harness between each control board. Replace harness if defective.
3. If harness is good and problem persists, replace the induction board indicated by the error code.
4. If problem persists, replace the hob user interface board corresponding to the error.
E20 LossofcommunicationbetweencooktopUI
and oven UI
1. Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. Test wiring harness between oven user interface board (MACS Bus) and cooktop UI (MACS2 or MACS1).
3. If wiring harness is good replace oven UI.
4. If the problem persists replace the cooktop user interface corresponding to the error.
E22 Lossofcommunicationbetweenpowerboardand
user interface board
1. Check the MACS connection (communication harness) between user interface board and induction power boards.
2. If problem persists, check continuity of MACS harness between each control board. Replace harness if defective.
3. If harness is good and problem persists, replace the induction board indicated by the error code.
4. If problem persists, replace the hob user interface board corresponding to the error.
E24 Lossofcommunicationbetweenthehobuser
interfaces
1. Check the MACS connection (communication harness) between hob user interface board and oven user interface.
2. If problem persists, check continuity of MACS harness between each control board. Replace harness if defective.
3. If harness is good and problem persists, replace the hob user interface board indicated by the error code.
4. If problem persists, replace the oven user interface board.
E25 Lossofcommunicationbetweenthepower
boards
1. Verify the unit has the proper cooktop user interface board based on the model number and parts catalog.
2. Replace the cooktop user interface board if the UI is incorrect or the issue persists.
E27 MACScongurationcommunicationloss 1. Check the MACS connection (communication harness) between user interface board and induction power boards.
2. If problem persists, check continuity of MACS harness between each control board. Replace harness if defective.
3. If harness is good and problem persists, replace the induction board indicated by the error code.
4. If problem persists, replace the hob user interface board corresponding to the error.
E50 ADC read error 1. Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the hob user interface corresponding to the error.
E61 15v supply out of window on induction power
board
1. Cycle power to the appliance, wait 30 seconds before reconnecting power.
2. If problem persists, replace the induction board indicated by the error code.
E64 Cooling fan on the induction power board is
blocked or otherwise unable to turn.
1. Check for interference, blockages, debris, dust, or anything else that would physically prevent the fan from moving.
2. If problem persists, replace the induction board indicated by the error code.
E81 Cooling fan not connected on induction power
board
1. Check cooling fan connections on the induction board indicated by the error code.
2. If problem persists, replace the induction board indicated by the error
Additional Failure Conditions
Symptom or Failure Control Display Possible Cause or Condition Suggested Corrective Action
Pan does not heat up. Normal operation Pan too small for proper pan detection and
only works with low power.
Use larger pan or this pan on a smaller cooking zone. Refer to owners guide for proper pan selection.
Flashing power level Display
and pan does not heat.
Pan not detected. Check whether the pots or pans are suitable for induction. Refer to owners guide for proper pan selection.
Induction surface unit not correctly connected
or surface unit open.
Check the surface unit wire terminal connections. Ensure that they are properly connected and tightened. Test continuity of element
(should be less than 1 ohm).
Distance between surface unit and glass
ceramic too large.
Check whether the surface unit is properly positioned and touching the glass cooktop surface.
Individual buttons cannot be used
or cannot always be used.
None 1. Test cables and connections.
2. Membrane control panel defective.
3. EOC defective.
1. Follow instructions for proper use of controls.
2. Verify membrane tail connections between EOC and ESEC. Replace if defective or damaged.
3. Replace EOC.
Cooking power too low or shuts
down prematurely.
None Fluids spilled or object lying on control panel
keypads.
Clean up spills or remove objects. Restart cooktop in normal manner.
Normal Operation Ventilation slots obstructed. Clear vent openings.
Unsuitable pots (bottom bent). Follow owner's guide for proper pan selection.
Distance between surface unit and glass
ceramic too large.
Check whether the surface unit is properly positioned and touching the glass cooktop surface.
Fan does not start. 1. With two cook zones operating, verify that the fan runs at a slow speed. If fans do not run, check for foreign objects or stuck fan
motor.
2. Test continuity of motor windings. Replace motor if open.
3. Replace induction control assembly.
Steady "Hot surface" indicator light
when cooking zone is cold and
switchedo.
"Hot surface" indicator light Induction coil temperature sensor failure 1.Test surface unit RTD approx. 100K ohms at room temperature. Replace surface unit if resistance is not correct.
2. Replace induction generator board.
Cooktop does not initialize/operate. Blank
No display
No beep
EOC not powered. Verify installation and harness connections to EOC.
Defective EOC. Replace EOC.
ÉLÉMENT DE CONVECTION
ÉLÉMENT DE CUISSON
MOTEUR VERROU
INTERRUPTEUR DE PORTE
VENTILATUER DE CONV
LAMPE DU FOUR
VENTILATEUR DE REFROIDISSEMENT
MISE À LA TERRE
CONTRÔLE
SONDE À VIANDE
SONDE À TEMPÉRATURE
INTERRUPTEUR DE PORTE
INTERRUPTEUR DU
LOQUET MOTORISÉ
DE LA PORTE
OPTIONNEL
MISE À
LA TERRE
À LA CUISINE
BLOC DE BORNES
CONDENSATEUR
MISE À LA TERRE
TEMPERATURE DU CAPTEUR
TEMPERATURE DU CAPTEUR
TEMPERATURE DU CAPTEUR
TEMPERATURE DU CAPTEUR
INDUCTEUR AVANT GAUCHE
INDUCTEUR ARRIERE GAUCHE
INDUCTEUR AVANT DROIT
INDUCTEUR ARRIERE DROIT
CÔTÉ GAUCHE
CÔTÉ DROIT
CARTE DE CIRCUIT DE GENERATEUR
CARTE DE CIRCUIT DE GENERATEUR
ASSIETTE
ASSIETTE
NOYAU MAGNÉTIQUE
(3 tours)
ASSIETTE