Dimensions Guide
INSTALLATION SPECIFICATIONS
•
Product Shipping Weight (approx.) – 275 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only
electrical supply with ground required on separate circuit fused on both sides
of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts = 7.9/5.9 kW
•
Amps @ 240 / 208 Volts = 30.38 / 35.25 Amps
•
Recommended Circuit Breaker – 30 Amps
•
Always consult local and national electric codes.
•
Minimum 21" clearance for oven door depth when open.
•
Suggested distance from floor is 11-1/2". Minimum required distance is 4-1/2".
•
To adapt Microwave Combination Oven to fit cutout height greater than
41-11/16", add one 2"-wide wood shim of appropriate height to each side of
opening under oven side rails. Lifting oven will hide larger cutout opening
at top and oven’s 1"-high bottom trim will hide shims at bottom. (Standard
1"-High Bottom Trim included.)
•
To adapt Microwave Combination Oven to fit cutout height greater than
42-3/16", optional 3"-High Bottom Trim available.
•
Minimum 24" deep cutout dimension is critical for proper installation, to ensure
that oven’s faceplate will fit flush against cabinet front.
•
Full oven base of solid plywood or similar material required, capable of
supporting 225 Lbs.
•
Base must be level and cabinet front must be square.
•
Microwave Combination Ovens are NOT approved to be used in stackable or
side-by-side installation.
OPTIONAL ACCESSORIES
•
3"-High Stainless Steel Bottom Trim – (PN # 5304520626).
•
3"-High Black Stainless Bottom Trim – (PN # 5304520622).
•
10'-Long Armored Power Cable – (PN # 903056-9010).
Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
*Critical dimension – MUST be applied
3" max.
1
1
/4"
min.
1"
min.
11
1
/2"
suggested
distance
4
1
/2"
min.
required
41
1
/8"
3
/4"
min.
41
1
/4"
max.
Full base
required
to support
225 lbs.
27
1
/8"
min.
4" x 4"
opening
to route
armored
cable (right
or left side
depending
on model)
24
7
/8"
min.
25
1
/4"
max.
23
min.
*
(critical
dimension)
2"-wide
wood spacers
(if needed)**
Electrical
junction box
location (right
or left side)
Spacer
24
5
/8"
42
4
/5"
(includes
1"
bottom
trim)
1
15
/16"
24
3
/4"
27"
40
1
/5
"
Allow at least
21" clearance
for door depth
when open
Power
supply
location
(middle
bottom
rear)
FGMC2766U 02/19
© 2019 Electrolux Home Products, Inc.
FGMC2766U D/F
MICROWAVE COMBINATION OVEN
27" ELECTRIC