Dimensions Guide

Specifications
subject to change.
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FHWC3650R 03/16 © 2016 Electrolux Major Appliances, NA Printed in Canada
Accessories information available
on the web at frigidaire.ca
Overhead Hood
FHWC3650RS 36" Under-Cabinet
Ensure there is proper clearance within ceiling, wall or cabinet
BEFORE making cutouts.
When installing vent hood under cabinets with recessed bottoms,
two 2"-wide filler strips required with length and thickness determined
by recess dimensions.
Framing for hood support MUST be capable of supporting 100 lbs.
Ducting Option Specifications
Vent system MUST terminate outside through roof; do NOT terminate
into attic or other enclosed area.
Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum
vent length. Refer to Product Installation Guide on web for calculations
needed to determine total duct length.
To provide efficient performance, length of vent system and number
of elbows should be kept to minimum. Flexible vent greatly reduces
performance and is NOT recommended.
Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent
recommended; plastic or metal foil vent NOT recommended.
For cold weather installation, additional backdraft damper and thermal
break should be installed. Thermal break will minimize conduction of
outside temperatures as part of the vent system with damper on cold
air side of break, as close as possible to where vent system enters
heated portion of house.
Refer to Product Installation Guide on web for detailed vent system
preparation instructions.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.ca for detailed instructions.
Under-Cabinet Vent Hood
FHWC3650R
Frigidaire Professional
36" base
cabinet height
to floor
36"
Height allowed from bottom
of hood canopy to cooking surface –
24" min. (elec.) / 27" min. (gas) / 30" sugg. max.
Exhaust
Vent hood is vertically ducted outside
using
3
1
/4" x 10" rectangular duct. For detailed
duct preparation and installation specifications,
refer to installation instructions on web.
Cabinet Bottom
5
1
/4"5
1
/4"
Vertical duct
cutout
Electrical access hole (in cabinet bottom)
2"-wide wood filler strips required for
recessed cabinet bottoms only
*From wall, NOT cabinet frame
5
/8" *
1
1
/2" *
C
L
Rear
Wall
3"
3"
3"
3"
Filler strip mounting screw holes (4)
1
1
/4"
dia.
8
3
/8"
4"
10
1
/2"
20"
36"
3"
3
1
/4" x 10" rectangular
duct location
Power supply
locations (top & rear)
35
3
/8"
13
3
/4"
7
3
/4"
33
1
/4"
4"
9"
Under-Cabinet Hood Specifications
Product Shipping Weight (Approx.) – 52 Lbs.
Under-Cabinet Installation – must be ducted vertically.
Ventilation system exhausts air outside vertically through roof.
(Refer to Ducting Option Specifications for outside ventilation.).
Sones Rating – 3.0 – 6.6
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = .33 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @ 120 Volts = 2.75 Amps
Always consult local and national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
Makeup air systems may be required by local building codes
when using ventilation systems greater than specified CFM of air
movement. Specified CFM varies per locale.
Connect vent hood with copper wire only. (For installation pre-wired
with aluminum wiring, refer to Product Installation Guide on web for
correct wiring procedure.)
Locate vent hood away from strong draft areas, such as windows,
doors or strong heating vents.
24" (electric) / 27" (gas) minimum installation height allowed
from bottom of hood canopy to cooking surface; 30" maximum
height suggested.