Installation Guide

Electric Dryer
Don’t Move
White Wire
Move
White Wire
White
Wire
Green
Wire
Black
or
Red
Wire
Install
U.L.-Approved Strain Relief
30 AMP 30 AMP
Connect to Gas or Electric
For detailed information, refer to the
Use & Care instruction provided with
this laundry center.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
5
Level and Connect
1. Use adjustable pliers to adjust the leveling legs so the laundry center is
level front-to-rear and side-to-side, and stable corner-to-corner
2. Connect power.
For detailed information refer the Use & Care instruction provided with
this laundry center.
WARNING - RISK OF FIRE
Ensure the entire dryer exhaust system is clean and free of lint and debris prior to the
installation of your new laundry center. The entire exhaust system should be inspected and
cleaned a minimum of every 18 months with normal usage. Failure to comply with cleaning
your exhaust system will increase the RISK of FIRE.
DO NOT install a clothes dryer with exible plastic or exible foil venting material. Flexible
venting materials are known to collapse, be easily crushed and trap lint. These conditions will
obstruct clothes dryer airow and increase the risk of re.
DO NOT screen the exhaust ends of the vent system, or use any screws, rivets or other
fasteners that extend into the duct to assemble the exhaust system. NO screen or grate of
any mesh size is allowed to cover the outdoor exhaust opening.
Install the laundry center according to the manufacturer’s instructions and local codes.
Laundry Center installation and service must be performed by a qualied installer, service
agency or the gas supplier.
The electrical service to the dryer must conform with local codes and ordinances and the
latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian
Electrical Code CSA C22.1 part 1.
The laundry center is designed under UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for
HOME USE only. This laundry center is not recommended for commercial applications such as
restaurants, beauty salons, etc.
Destroy the carton and plastic bags after the laundry center is unpacked. Children might use
them to play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight
chambers causing suocation. Place all materials in a garbage container or make materials
inaccessible to children.
The instructions in this manual and all other literature included with this dryer are not meant to
cover every possible condition and situation that may occur. Good safe practice and caution MUST
be applied when installing, operating and maintaining any appliance.
A17468405 (2202)
For support in the U.S. call 1-877-4ELECTROLUX (1-877-435-3287) or visit www.electroluxappliances.com. For support in Canada call 1-800-265-8352 or visit www.electroluxappliances.ca.
TO INSTALLER:
Leave these instructions with the customer.
*Please refer to the Use & Care instruction booklet provided with this laundry center for further details.
Installation
*
for Frigidaire Laundry Center
1
For detailed information, refer to the
Use & Care instruction provided with
this laundry center.
6
Installation Checklist
Shipping hardware
Foam shipping restraint (inside wash tub)
removed and stored
Foam shipping support (underneath
appliance) removed and stored
Leveling
Laundry center is level, side-to-side and
front-to-back
Cabinet is setting solid on all corners
Water supply
Use only new hoses and verify rubber
sealing washers are installed
HOT supply is connected to HOT inlet and
COLD supply is connected to COLD inlet
HOT and COLD water supply turned on
No leaks present at water supply
connections or appliance inlet connections
-recheck in 24 hours
Drain
Stand pipe or wall drain height min. 33”
Drain hose secured in place with cable tie
(shipped in drum)
Exhaust venting
Free-owing, clear of lint buildup
End of exhaust vent securely fastened
to exhaust port to prevent air leaks and
excess noise
4 inch (102 mm) rigid or semi-rigid
ducting of minimal length and turns
NO foil or plastic venting material
Approved vent hood exhausted to
outdoors
240V electric supply
(electric dryer)
Approved NEMA 10-30R or 14-30R
service cord with all screws tight on
terminal block
Approved strain relief installed
Terminal access cover installed before
initial operation
Electrical power
House power turned on
Laundry Center plugged in
Final checks
Installation Instructions and Use & Care
instruction read thoroughly
Water enters drum when cycle starts with
lid lowered and dryer door latches and
drum tumbles when cycle starts
Registration card sent in
For detailed information, refer to Use & Care instruction provided with this
laundry center.
Connecting to the drain
1. Form a “U” shape on the end of the drain
hose with the hose pointed toward the drain.
2. Place the formed end in a laundry tub or a
standpipe and secure the drain hose with
the cable tie (provided in the enclosure
package) to the standpipe, inlet hose,
laundry tub, etc. so the hose does not pull
out from the force of the water.
WARNING
ELECTRICAL SHOCK HAZARD
A U.L. approved strain relief must be
installed onto power cord. If the strain relief
is not attached, the cord can be pulled out of
the dryer and can be cut by any movement
of the cord, resulting in electrical shock.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT use an aluminum wired receptacle
with a copper wired power cord and plug
(or vice versa). A chemical reaction occurs
between copper and aluminum and can
cause electrical shorts. The proper wiring and
receptacle is a copper wired power cord with a
copper wired receptacle.
2
Electrical requirements
Since your laundry center is equipped with
a power supply cord having an equip-
ment-grounding conductor and a grounding
plug, the plug MUST be plugged into an appro-
priate, copper wired receptacle that is properly
installed and grounded in accordance with all
local codes and ordinances or in the absence of
local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition), or in Canada,
the Canadian electrical code C22.1 part 1. If in
doubt, call a licensed electrician.
DO NOT cut o or alter the grounding prong on
the power supply cord. In situations where a
two-slot receptacle is present, it is the owner’s
responsibility to have a licensed electrician
replace it with a properly grounded three prong
grounding type receptacle.
Electric dryer
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers.
POWER SUPPLY - 3-wire or 4-wire, 240 volt,
single phase, 60 Hz, Alternating Current. The
power cord is NOT supplied with unit.
OUTLET RECEPTACLE - NEMA 10-30R or
NEMA 14-30R receptacle to be located so
the power supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding
requirements” in Use & Care instructions. The
laundry center MUST be grounded. In the
event of malfunction or breakdown, grounding
will reduce the risk of electrical shock by a
path of least resistance for electrical current.
WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment grounding conductor can cause an electrical shock that
may result in serious injury or death. Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
IMPORTANT
Please review “Troubleshooting” in your Use & Care instruction before calling for service.
4
Connect to Water Line and Drain
Connecting to the water line
1. Run some water from the hot and cold
faucets to ush the water lines and remove
particles that might clog the water valve
screens and to determine which faucet is
hot and which is cold supply.
2. Check to ensure that the inlet hoses have
the rubber washer rmly in place. Use only
new hoses.
3. Connect the HOT inlet hose to the HOT inlet
connection on the washer and the COLD
inlet hose to the COLD inlet connection
on the washer (cold on top). Tighten by
hand until snug. Then tighten each supply
connection another 2/3 turn with pliers.
DO NOT cross thread or over-tighten these
connections.
4. Connect the HOT inlet hose to the HOT
water supply and the COLD inlet hose to the
COLD water supply. Tighten by hand until
snug. Then tighten each supply connection
another 2/3 turn with pliers. DO NOT bend,
kink, or pinch water inlet hoses.
5. Turn on the water and check for leaks.
WARNING
FIRE HAZARD
Never exceed more than four-90˚ elbows in
the exhaust duct system.
Connect or Construct Vent Exhaust
Exhaust system must
be vented outside with
approved vent hood.
3
NO screen or grate
of any mesh size is
allowed to cover the
exhaust opening.
Use only 4 inch rigid or semi-rigid metal
ducting
Clean lint from duct system
Use only metal foil tape to connect ducts (no
screws)
DO NOT exceed 8 ft. (2.4m) total duct length if installing semi-rigid venting.
DO NOT install flexible plastic or flexible foil ducting material.
For detailed information, refer to the Use & Care instruction provided with
this laundry center.
Use 4" (10.2 cm) clamp to connect dryer &
exhaust system
Use 90° quick-turn elbow to vent left or right
from dryer
Correct
Incorrect
Correct
Incorrect
Max. Number of 90° turns
MAXIMUM LENGTH
of 4” (102 mm) Rigid Metal Duct
LONG VENT MODELS ONLY FLCE7523AW
VENT HOOD TYPE
4” (10.2 cm) louvered 2.5” (6.35 cm)
0 127 ft. (39 m) 124 ft. (37 m)
1 117 ft. (35 m) 114 ft. (34 m)
2 107 ft. (32 m) 104 ft. (31 m)
3 97 ft. (29 m) 94 ft. (28 m)
4 87 ft. (26 m) 84 ft. (25 m)
DANGER
If using LP (Liquid Propane) STOP and install the LP kit before operating your gas
dryer.

Summary of content (3 pages)