User manual

Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
KW
REDUCED POWER KW
INJECTOR MARK
1/100 MM
Rapid 3.0 0.75 119
Semi-rapid 2.0 0.45 96
Auxiliary 1.0 0.35 70
Oven 2.25 1.0 108
Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL POWER
KW
REDUCED POWER KW
INJECTOR MARK
1/100 MM
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 2.25 1.0 71
Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not
used must be clogged with the pipe closer,
which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible
metallic pipes, make sure they do not come
in touch with mobile parts and they are not
squeezed.
Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.
29