Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL POW-
ER KW
GAS RATE G/H
REDUCED POWER
KW
INJECTOR MARK
1/100 MM
Rapid 3.0 218.1 0.72 88
Semi-rapid 2.0 145.4 0.43 71
Auxiliary 1.0 72.7 0.35 50
Oven 2.25 163.6 1.0 71
Grill 2.0 145.4 1.5 71
Gas connection
WARNING!
Before you connect the gas,
disconnect the appliance from the
electricity supply or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not
used must be clogged with the pipe closer,
which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible
metallic pipes, make sure they do not come
in touch with mobile parts and they are not
squeezed.
WARNING!
When installation is complete, make
sure that the seal of each pipe fitting
does not leak. To check the seal use a
soap solution, not a flame.
Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
it can not get hotter than room
temperature, higher than 30 °C,
29