User manual

BURNER Ø BYPASS 1/100 MM
Oven 54
Grill 54
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
KW
REDUCED POWER KW
INJECTOR MARK
1/100 MM
Triple Crown 4.0 1.8 146
Rapid 3.0 0.72 119
Semi-rapid 2.0 0.43 96
Auxiliary 1.0 0.35 70
Oven 3.9 1.5 136
Grill 3.0 1.6 126
Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL POWER
KW
REDUCED POWER KW
INJECTOR MARK
1/100 MM
Triple Crown 4.0 1.8 101
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 3.9 1.5 95
Grill 3.0 1.6 88
Gas connection
WARNING!
Before you connect the gas,
disconnect the appliance from the
electricity supply or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not
used must be clogged with the pipe closer,
which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible
metallic pipes, make sure they do not come
in touch with mobile parts and they are not
squeezed.
30
INSTALLATION