A) Gas connection point (only one point is
applicable for the appliance)
B) Gasket
C) Adjustable connection
D) Natural Gas pipe holder
E) LPG pipe holder
Adjustment to different types
of gas
WARNING!
Let only an authorized person do the
adjustment to different types of gas.
This appliance works with liquid gas.
With the correct injectors, you can also
operate it with natural gas. The gas
rate is adjusted to suit.
WARNING!
Before you replace the injectors, make
sure that the gas knobs are in the Off
position. Disconnect the appliance
from the electrical supply. Let the
appliance cool down. There is a risk of
injury.
Hob injectors replacement
Replace the injectors when you change the
gas type.
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. Remove the injectors with a socket
spanner 7.
4. Replace injectors with the ones
necessary for the type of gas you use.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply.
You can find this plate in the bag
supplied with the appliance.
If the supply gas pressure is not constant or
it is different from the necessary pressure,
install an applicable pressure adjuster on
the gas supply pipe.
Adjustment of minimum level
at the hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there is
no access to the bypass screw
dismount the control panel before
adjustment start.
3. Adjust the bypass screw (A) with a thin
and flat screwdriver.
Positions of the bypass screw (A)
depends on model.
31