Installation Instructions

7
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker,fuseboxorjunctionbox,useexible,
armored or nonmetallic sheathed copper cable
(with grounding wire). Supply a U.L. listed strain-
relief at each end of the cable. At the appliance
end, the cable goes through the Direct Connection
Hole(seeFigure9)ontheCordMountingPlate.
Wire sizes (copper wire only) and connections
must conform to the rating of the appliance.
Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (see Figure 10):
1. Be sure that no power is supplied on the cable
from residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box
(Fig. 10):
a) Connect the green (or bare copper) wire,
the white appliance cable wire, and the neutral
(white) wire together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Figure 10
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Cable from Residence
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Cable from
Appliance
Green
(or Bare
Copper) Wire
Red
Wires
Neutral
(white) Wire
Black
Wires
NOTE: Be sure to remove
the supplied grounding strap.
Where local codes DO NOT permit connecting
the appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 11):
1. Be sure that no power is supplied on the cable
from residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box
(Fig. 11):
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit
breaker, fuse box or junction box.
Figure 11
4-Wire Electrical System (Example: Junction Box)
NOTE: Be sure to remove the
supplied grounding strap.
U.L.-listed Conduit
Connector (or CSA
listed)
Cable from
Residence
Black
Wires
Junction
Box
White Wire
Cable from
Appliance
Green (or Bare
Copper) Wire
Red
Wires
White
Wire
Green (or Bare
Copper) Wire
6. Checking Operation
Refer to the Use and Care Guide for operation.
CAUTION
Do not touch cooktop glass or
elements. They may be hot enough to burn you.
Before You Call for Service
Read the Before You Call for Service Checklist
and operating instructions in your Use and Care
Guide. It may save you time and expense. The
list includes common occurrences that are not the
result of defective workmanship or materials in this
appliance.
Refer to your Use and Care Guide for Sears service
phone numbers, or call 1-800-4-MY-HOME
®
.