Product Specifications Sheet

Specifications
subject to change.
Freestanding Range
FPEH3077RF 30" Electric
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FPEH3077R 11/15 © 2015 Electrolux Home Products, Inc.
Front
29
7
/8"
Side
26"
28
3
/4"
30" Electric Freestanding Ranges with Front Controls (FC)
Professional - New Handles (P2)
25"
max.
30"
min.
13"
max.
24"
Minimum
1"clearance
required
to nearest
combustible
wall on
either side
of range
above 36"
height
6"
2
1
/2"
Shaded areas allow for flush-to-wall installation
of rear wall electrical outlet. (All dimensions
for outlet location are maximum.)
C
L
9"
36"
stand.
30"
min.*
Wall
18"
min.
18"
min.
9"
3"
3"
30
1
/8"
*Note: 30"
minimum clearance between top of cooking
surface and bottom of unprotected wood or metal
overhead cabinet; or 24"
minimum clearance when
bottom of wood or metal overhead cabinet is protected
by not less than 1/4" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or 0.020" copper.
0"
clearance is minimum for rear of range. Follow all
dimension requirements provided above to prevent
property damage, potential fire hazard, and incorrect
countertop and cabinet cuts.
46
"
Power cord location
(left bottom rear*)
*when viewed from front
36
3
/8"
(Adjustable
to
±
1
/4")
Note: Overall
product dimensions
are model specific
and may vary slightly
from illustration. Refer
to model’s product
specifications for
actual dimensions.
Freestanding Range Specifications
Product Shipping Weight (approx.) – 300 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz,
fused on both sides of line with ground.
Connected Load (kW Rating) @ 240 / 208 Volts = 13.0 / 9.8 kW
Recommended Circuit Breaker – 40 Amps
Always consult local and /or national electric codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
Minimum 1" clearance required from edge of rangetop to nearest
combustible wall on either side of range above 36" height.
Allow 30" minimum clearance between top of cooking surface and
bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/4" flame retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Griddle – (PN # 316432200).